FOR WET OPERATION:
With HEPA filter and water pick-up pan in place, securely clamp
motor head to the spacer. When the maximum water level in the
vacuum cleaner tank is reached the water pick-up pan's safety valve
(float) closes off suction, automatically preventing further
liquid intake.
NOTE: This will cause the motor to race. Turn off motor, remove
and empty tank. Thoroughly clean float assembly.
Replace water pick-up adapter, HEPA filter and motor head, then
clamp securely. The vacuum cleaner is ready for wet use.
When removing the motor head, care in handling is essential. Dropping, banging or other abuse may result in poor vacuum seal and
a loss in suction power, and will invalidate your warranty.