Page 1
PRINCESS PE32 SOLID FUEL CATALYTIC STOVE PE32 Firebox with PE32 Firebox with PE32 Firebox with Z4786 Door and Z4786 Door and Z4786 Door and Z1713 Parlor Leg Kit Z3284 Classic Base Kit Z3903 Ultra Pedestal Kit U.S. Environmental Protection Agency certified to comply with 2020 particulate emission standards using crib wood.
PE32 INTRODUCTION Page 4 • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED BY FEDERAL AND STATE LAWS. Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating •...
This unit was tested and listed UL 1482-2011(R2015) and ULC-S627-00 EMISSIONS CO Average(%) g/hr (R2016) by PFS testing laboratories. Low Burn 0.29 0.21 This manual describes the installation and operation of the Princess PE32 Med-low Burn 0.09 0.13 catalytic equipped wood heater. Med-high Burn 0.31 0.52 This heater is certified to comply with the 2020 U.S.
Page 6
PE32 PRODUCT INFORMATION Page 6 APPLIANCE DIMENSIONS - Princess PE32 with Door and Parlor Leg Kit " " 3" " " " " 9 " " 27" 180-PE32 v1.01 May 27, 2020...
Page 7
PE32 PRODUCT INFORMATION Page 7 APPLIANCE DIMENSIONS - Princess PE32 with Door and Classic Base Kit " " 3" " " " " " " 27" 180-PE32 v1.01 May 27, 2020...
Do not install in a sleeping room. Passing through a wall or ceiling requires special methods: see instructions and local building codes. POUR PRÉVENIR UN INCENDIE - Installer et employer seulement selon le manuel d’installation de Blaze King. Contacter les autorités locales en bâtiments ou en matière de prévention d'incendies au sujet des normes d'inspection et d'installation dans votre secteur.
SAFETY PRECAUTIONS Page 10 IF THIS BLAZE KING APPLIANCE IS NOT PROPERLY INSTALLED OR OPERATED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
Page 11
PE32 SAFETY PRECAUTIONS Page 11 Never try to repair or replace any part of this appliance Do not place clothing or other unless instructions are given flammable items on or near in this manual. All other work this appliance. must be done by a trained technician.
Page 12
PE32 SAFETY PRECAUTIONS Page 12 This appliance is designed and approved for burning cord wood only. DO NOT burn garbage or flammable fluids such as gasoline, naphtha or engine oil; artificial or paper logs; gift wrappings; coal; lighter fluids; chemical cleaners; chemical starters; treated or painted wood;...
CAN CATCH FIRE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”(1219 MM) FROM THE FRONT OF THE APPLIANCE. Blaze King grants no warranty, implied or stated, for the installation or maintenance of the appliance and assumes no responsibility of any consequential damage(s).
Poor draft can also lead to poor heat production and the inability for the combustor to remain active in lower burn rate settings. High efficiency appliances, such as your Blaze King stove, may require some fine tuning of your chimney system in order to maximize performance.
PE32 INSTALLATION INSTRUCTIONS Page 16 VENTING SYSTEMS The venting system consists of a chimney connector and a chimney. These get extremely hot during use. Temperatures inside the chimney may exceed 2000 degrees in the event of a creosote fire. To protect against the possibility of a house fire, the chimney connector and chimney must be properly installed and maintained.
Page 17
PE32 INSTALLATION INSTRUCTIONS Page 17 CONNECTION TO A METAL PREFABRICATED CHIMNEY Refer to “RECOMMENDED FLUE HEIGHTS” chart for minimum flue height recommendations and ULC629 in Canada or UL-103HT in the USA for installation codes. When a metal prefabricated chimney is used, the manufacturer’s installation instructions must be followed precisely.
Page 18
1” clear of the wall. ***Blaze King recommends the use of a Stainless steel liner, preferably insulated, inside a masonry chimney. This is to maintain proper draft and overall better operation of the unit.
PE32 INSTALLATION INSTRUCTIONS Page 19 RECOMMENDED FLUE HEIGHTS 1. At sea level the minimum height is a 15 ft (4.6 m) straight run. 2. Add the following vertical height to the flue to compensate for: 45° elbow = 1.0 ft (.30 m) 90°...
PE32 INSTALLATION INSTRUCTIONS Page 20 MOBILE HOME (AND RESIDENTIAL ALCOVE INSTALLATIONS) Requires outside air kit, and either rear shield OR fan kit. (See next page for kits and part numbers). The outside air kit is easiest to mount before the stove is installed. See instructions packed with each kit. NOTE: UNDER NO CIRCUMSTANCES SHOULD THE FRESH AIR TUBE EVER BE INSTALLED HIGHER THAN THE BOTTOM OF THE APPLIANCE FIREBOX FLOOR.
NOTE: Fan Kit should be installed before the stove is placed into position ELECTRICAL CONNECTION: Your Blaze King fan kit is equipped with a three-prong (grounded) plug to decrease shock hazard. THIS PLUG SHOULD BE INSERTED DIRECTLY INTO A PROPERLY-GROUNDED, THREE-HOLE RECEPTACLE. DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG.
PE32 INSTALLATION INSTRUCTIONS Page 22 PARLOR LEG KIT (S.Z1713.BK) NOTE: EITHER S.Z1713.BK PARLOR LEG KIT, S.Z2384 CLASSIC BASE KIT, OR S.Z3903.BK ULTRA PEDESTAL KIT, MUST BE INSTALLED BEFORE STOVE CAN BE DUCTED AND READY FOR USE. TOOLS NEEDED FOR INSTALLATION: 3/4” wrench or socket wrench INSTALLATION 1.
PE32 INSTALLATION INSTRUCTIONS Page 23 CLASSIC BASE KIT (S.Z3284) NOTE: EITHER S.Z1713.BK PARLOR LEG KIT, S.Z2384 CLASSIC BASE KIT, OR S.Z3903.BK ULTRA PEDESTAL KIT, MUST BE INSTALLED BEFORE STOVE CAN BE DUCTED AND READY FOR USE. TOOLS NEEDED FOR INSTALLATION: 7/16” and 3/4”...
PE32 INSTALLATION INSTRUCTIONS Page 24 PEDESTAL KIT (S.Z3903.BK) NOTE: EITHER S.Z1713.BK PARLOR LEG KIT, S.Z2384 CLASSIC BASE KIT, OR S.Z3903.BK ULTRA PEDESTAL KIT, MUST BE INSTALLED BEFORE STOVE CAN BE DUCTED AND READY FOR USE. TOOLS NEEDED FOR INSTALLATION: 7/16” wrench or socket wrench INSTALLATION 1.
PE32 INSTALLATION INSTRUCTIONS Page 25 DOOR INSTALLATION AND CHANGE-OUT To install the door upon stove installation or to change it out, follow these steps: WARNING: DOOR IS HEAVY, PLEASE HOLD FIRMLY. INSTALLATION 1. Align bottom door hinge hole with bottom firebox hinge pin. (Fig. 11) 2.
Consequential damage from this type of operation will deem the warranty null and void. All Blaze King wood appliances are designed to burn cord wood only. Dimensional timber off cuts, very low moisture content small diameter wood and pressed wood logs, when used in excess, may result in excessive internal firebox temperatures that can cause causing irreversible damage to the firebox’s internal structure.
PE32 OPERATING INSTRUCTIONS Page 27 THERMOSTAT The thermostat knob is located on the top right rear corner of the stove. It controls the burn rate of the stove. Any thermostat position between LOW(thin line) and HIGH(wide line) will produce the desired clean burning characteristics.
The more seasoned (dry) the wood, the higher the efficiency (less energy wasted on eliminating moisture during combustion). Operating your Blaze King at lower settings will result in higher efficiencies as the fuel will undergo a more complete combustion. For maximum efficiency, the appliance should be installed in a location that provides adequate intake/combustion air as well as a location that will allow for the straightest run of optimal chimney length to establish necessary draft .
Don’t be afraid to fill it completely if necessary. With the Blaze King automatic thermostat, the wood will only burn at the rate set on the thermostat.
PE32 OPERATING INSTRUCTIONS Page 30 DO NOT USE THE APPLIANCE WITHOUT A COMBUSTOR RELOADING PROCEDURE (with the catalyst temperature in the ACTIVE ZONE) DO NOT RELOAD IF THE CATALYTIC THERMOMETER NEEDLE IS HIGHER THAN THE POSITION SHOWN HERE 1. Have your next load of wood ready before beginning. Turn the thermostat to HIGH and the fan(if fitted) OFF.
PE32 OPERATING INSTRUCTIONS Page 31 OPTIMAL THERMOSTAT SETTING Any thermostat position between LOW and HIGH will produce the desired clean burning characteristics. However, since each application can vary, you may find it necessary to operate the thermostat to suit your application.
It is also possible that the thermometer, itself, may not be reading accurately. Before condemning the combustor, read “THERMOMETER”. If, after cleaning has been performed, your combustor is still not working you can Contact Blaze King for a replacement combustor. Please read “REPLACEMENT PARTS” section in this owners’ manual.
Solution: Burn quality woods available in your area. If you decide the catalyst has been deactivated, replace combustor with a genuine Blaze King combustor (failure to do so will void your warranty). Severe Peeling 180-PE32 v1.01...
Page 34
PE32 CATALYST MONITORING Page 34 PROBLEM - CATALYST MASKING (The catalyst is coated with a layer of fly-ash or soot which prevents catalytic activity) Possible Cause: Accumulation of fly-ash Solution: Brush cooled combustor with a soft-bristled brush or vacuum lightly at least once per burning season. PROBLEM - THERMAL CRACKING Possible Cause: Normal operation, as long as the combustor remains intact.
CATALYST MONITORING). If the combustor needs replacing then discontinue use of the appliance until the combustor is replaced. If the combustor must be examined or replaced contact your Blaze King dealer. 1. The removal of a Blaze King Catalytic combustor requires a small flat blade screwdriver or pocket knife.
Page 36
PE32 CATALYST MONITORING Page 36 4. Now that the combustor has been removed you’ll be able to see one stainless bypass retainer on each side. These can remain in place and do not need to be removed. These clips are not fixed in position and can fall into the firebox.
Page 37
The combustor supplied with this heater is either a 115-0556 or 115-0336-A-M metal combustor. Consult the catalytic combustor warranty also supplied with this wood heater. Warranty claims should be addressed to: in Canada in USA Blaze King Industries / Valley Comfort Systems Blaze King Industries Warranty Department, 1290 Commercial Way Warranty Department, 146A Street...
PE32 MAINTENANCE Page 38 RUN-AWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRE DAMAGE IS NOT COVERED BY THE LIMITED WARRANTY. CAUSES: 1.
PE32 MAINTENANCE Page 39 CHIMNEY MAINTENANCE The most efficient method to sweep the chimney is using a hard brush. Brush downwards so soot and creosote residues will come off the inner surface and fall to the bottom of the chimney where they can be removed easily.
BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. If the door gasket is to be replaced, be sure you have Blaze King 7/8” fiber glass gasket ready to re- install, as well as high temperature adhesive. See your Blaze King dealer.
BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. Will require THERMOSEAL® 1000SF high-temperature resistant cement and Blaze King 5/8” dense fiber glass gasket. See your Blaze King dealer. You will also require masking tape and combustor gasket as disassembly of the combustor will result in a damaged combustor gasket.
DOOR GLASS GASKET REPLACEMENT BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. You will require Blaze King glass gasket and Blaze King door gasket. Please see your Blaze King dealer. 2. Remove the old glass gasket. 3. Starting at the corner opposite of the “Blaze King”...
PE32 MAINTENANCE Page 43 LOADING DOOR TENSION ADJUSTMENT To tighten the seal, use a 9/16” wrench to loosen retainer nut on the outside and tighten nut on inside firebox to move latch catch in (see figure beside). Secure retainer nut and (repeat) paper test.
“Inactive” zone, then retighten the bolt. NOTE: IF YOUR BLAZE KING IS EQUIPPED WITH FANS, TURN OFF FANS AND WAIT 10 MINUTES PRIOR TO READING CATALYTIC THERMOMETER INDICATOR. AIR MOVEMENT ACROSS THE TOP OF THE STOVE MAY PROVIDE FALSE READING.
Page 45 Your Blaze King is designed to allow a wide selection of heat output levels. If you begin to lose control of the amount of heat the stove is emitting, determine the cause early so that major problems may be avoided.
Page 46
INSPECTION” Excessive draft in the chimney. Measure draft with a Manometer. See “DRAFTS”. Consult your Blaze King dealer or a chimney sweep. Install a cap. Thermostat not operating properly. Consult your Blaze King dealer. Wood is too small.
Page 47
Consult your blaze King Dealer. By-pass door leaking or not closing completely. Inspect and clean area around by-pass doors. Adjust or replace gasket if necessary. Consult your Blaze King Dealer. PROBLEM: Spots of creosote accumulation in chimney or chimney connector. CAUSE SOLUTION Air leaks in chimney or chimney connector.
PE32 REPLACEMENT PARTS Page 48 exploded Part # Description view 155-0255-B-3ft BYPASS GASKET 5/8” DENSE ROUND S.CAT203032 COMBUSTOR S.Z4498 BYPASS RETAINER KIT S.Z4438.1 FLAME SHIELD S.Z4551 DOME GUARD REPLACEMENT KIT 155-0186-5ft DOOR GASKET 7/8” ROUND - 5 FT 130-0246 GLASS CERAMIC 5MM PE 155-0254-AS-4ft GLASS GASKET 1/8 x 3/4 301B W/PSA - 4 ft S.Z4786...
Page 49
PE32 REPLACEMENT PARTS Page 49 Brick Layout Part # A SIZE BRICK B SIZE BRICK FT SIZE BRICK I SIZE BRICK QC SIZE BRICK X SIZE BRICK 180-PE32 v1.01 May 27, 2020...
Page 50
PE32 REPLACEMENT PARTS Page 50 Z1714 Fan Kit Assembly exploded Part # Description ITEM NO. PART NUMBER DESCRIPTION QTY. view 0136 Rheostat with Off Switch 0137 Rheostat Knob silver Inlay 145-0136 RHEOSTAT WITH OFF (O/H/LOW) 0175C Fan Axial Spider mnt Muffin (Bay) 220-0137 RHEOSTAT KNOB BLACK SILVER LINE 150-0175-C FAN AXIAL SPIDER MOUNT...
Page 51 BLAZE KING WOOD LIMITED WARRANTY Blaze King and Valley Comfort’s respective brands extend the following warranty for wood fired appliances purchased from an authorized Blaze King / Valley Comfort dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
Page 52
Blaze King is the manufacturer of the Blaze King line of heating products. At Blaze King, our commitment to the highest level of quality and customer service is the most important thing we do. Each Blaze King stove is built on a tradition of using only the finest materials and is backed by our limited warranty to the original purchaser.
Page 53
Blaze King The use of such products may nullify the Limited Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Blaze King dealer before installation.
Page 54
20%. 3rd year ----purchaser pays 40%. 4th year -----purchaser pays 60%. 5th year---- purchaser pays 80%. If a defect or problem is determined by Blaze King to be non warrantable, Blaze King is not liable for travel costs for service work. In the event of in-home repair work, the customer will pay any in-home travel fees or service charges required by the Authorized Dealer.
PE32 INSTALLER NOTES Page 56 Installer: Please complete the following information Dealer Name & Address:________________________________________________________ ____________________________________________________________________________ Installer (print): _______________________________________________________________ Installer (sign): _______________________________________________________________ Phone #: ____________________________________________________________________ Date Installed:________________________________________________________________ Serial No.: ___________________________________________________________________ 180-PE32 v1.01 May 27, 2020...
Need help?
Do you have a question about the PRINCESS PE32 and is the answer not in the manual?