Blaze King PRINCESS PI29 Operation & Installation Manual

Solid fuel wood catalytic stove
Hide thumbs Also See for PRINCESS PI29:

Advertisement

Quick Links

PRINCESS PI29
SOLID FUEL WOOD CATALYTIC STOVE
U.S. Environmental Protection Agency certified to comply with 2020 particulate emission standards using crib wood.
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please SAVE THESE INSTRUCTIONS for future reference.
0142WN019E
0142WN019S
The authority having jurisdiction (such a municipal building department, fire department, etc.) should
be consulted before installation to determine the need to obtain a permit.
OPERATION & INSTALLATION MANUAL
Manufactured By
Valley Comfort Systems Inc., 1290 Commercial Way, Penticton, BC, V2A 3H5, Canada
Phone: 250-493-7444 - Fax: 250-493-5833 - www.blazeking.com - info@blazeking.com
Pour la version française de nos manuels S.V.P. vous référez à notre site web: www.blazeking.com
180-PI29 v1.08
September 27, 2021

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PRINCESS PI29 and is the answer not in the manual?

Questions and answers

Summary of Contents for Blaze King PRINCESS PI29

  • Page 1 PRINCESS PI29 SOLID FUEL WOOD CATALYTIC STOVE U.S. Environmental Protection Agency certified to comply with 2020 particulate emission standards using crib wood. Installer: Please complete the details on the back cover and leave this manual with the homeowner. Homeowner: Please SAVE THESE INSTRUCTIONS for future reference.
  • Page 2: Table Of Contents

    PI29 TABLE OF CONTENTS Page 2 _____________________________________________________________ 4 INTRODUCTION _____________________________________________________________ 5 SPECIFICATIONS __________________________________________________________________ 5 EMISSIONS ______________________________________________________ 6 APPLIANCE DIMENSIONS ......................6 S.Z4674 - 29” PI SHROUD ......................7 S.Z4676 - 33” PI SHROUD ________________________________________________________ 8 CERTIFICATION LABEL ________________________________________________________ 9 SAFETY PRECAUTIONS _________________________________________________ 12 INSTALLATION INSTRUCTIONS ..........................
  • Page 3 PI29 TABLE OF CONTENTS Page 3 ______________________________________________________________ 31 MAINTENANCE ....................31 RUN-AWAY OR CHIMNEY FIRE ..........................32 ASH REMOVAL ..................33 LOADING DOOR GASKET INSPECTION ................. 33 LOADING DOOR GASKET REPLACEMENT ..................34 BYPASS DOOR GASKET REPLACEMENT ................... 35 DOOR GLASS GASKET INSPECTION ..................
  • Page 4: Introduction

    PI29 INTRODUCTION Page 4 • THIS APPLIANCE IS HOT WHEN OPERATED AND CAN CAUSE SEVERE BURNS IF CONTACTED. ANY CHANGES OR ALTERATIONS TO THIS APPLIANCE OR ITS CONTROLS CAN BE DANGEROUS AND IS PROHIBITED BY FEDERAL AND STATE LAWS. Do not operate appliance before reading and understanding operating instructions. Failure to operate appliance according to operating •...
  • Page 5: Specifications

    0.31 1.59 This manual describes the installation and operation of the Med-low Burn 0.28 0.72 Princess PI29 catalytic equipped wood heater. Med-high Burn 0.60 1.27 This heater is certified to comply with the 2020 U.S. Environmental Protection Agency’s particulate emission High Burn 1.62...
  • Page 6: Appliance Dimensions

    PI29 APPLIANCE DIMENSIONS Page 6 S.Z4674 - 29” PI SHROUD " " " 43" 1092 " 30° 29" " " " " " " " " " 180-PI29 v1.08 September 27, 2021...
  • Page 7: S.z4676 - 33" Pi Shroud

    PI29 APPLIANCE DIMENSIONS Page 7 S.Z4676 - 33” PI SHROUD " " " 47" 1194 " 30° 33" " " " " " " " " " 180-PI29 v1.08 September 27, 2021...
  • Page 8: Certification Label

    PI29 CERTIFICATION LABEL Page 8 180-PI29 v1.08 September 27, 2021...
  • Page 9 SAFETY PRECAUTIONS Page 9 IF THIS BLAZE KING APPLIANCE IS NOT PROPERLY INSTALLED OR OPERATED, A HOUSE FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE INSTALLATION INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
  • Page 10: Safety Precautions

    PI29 SAFETY PRECAUTIONS Page 10 Never try to repair or replace any part of this appliance Do not place clothing or other unless instructions are given flammable items on or near in this manual. All other work this appliance. must be done by a trained technician.
  • Page 11 PI29 SAFETY PRECAUTIONS Page 11 This appliance is designed and approved for burning cord wood only. DO NOT burn trash, garbage; artificial or paper logs; gift wrappings; coal; lighter fluids; chemical cleaners; chemical starters; treated or painted wood; salt water driftwood or foil-backed paper such as gum wrappers or cigarette packages;...
  • Page 12: Installation Instructions

    CAN CATCH FIRE. OBJECTS PLACED IN FRONT OF THE APPLIANCE MUST BE KEPT A MINIMUM OF 48”(1219 MM) FROM THE FRONT OF THE APPLIANCE. Blaze King grants no warranty, implied or stated, for the installation or maintenance of the appliance and assumes no responsibility of any consequential damage(s).
  • Page 13 PI29 INSTALLATION INSTRUCTIONS Page 13 Minimum clearances to combustibles Side of door flange to combustible wall. 17in / 432 mm Top of door flange to bottom of 12” deep mantel shelf. 26in / 660 mm Top of door flange to combustible facing and trim (3/4” thick). 14in / 356 mm Side of door flange to side combustible facing.
  • Page 14: Combustion Air

    Poor draft can also lead to poor heat production and the inability for the combustor to remain active in lower burn rate settings. High efficiency appliances, such as your Blaze King stove, may require some fine tuning of your chimney system in order to maximize performance.
  • Page 15: Inspect Chimney

    PI29 INSTALLATION INSTRUCTIONS Page 15 INSPECT CHIMNEY Before connecting any wood-burning unit to an existing chimney, inspect the chimney to be sure that it is in good condition. There must be no cracks or holes. The cross-sectional area can differ from the flue collar as long as sufficient draw is maintained and local codes and jurisdiction are observed..
  • Page 16: Stove Assembly

    3/8” NC nut. If required a 3/8” bolt of determined length can be threaded into these nuts to assist in leveling the unit. NOTE: Blaze King strongly recommends that you install a complete insulated stainless steel flue liner system. This is the safest installation and will ensure proper draft control for ideal and consistent burn times.
  • Page 17 PI29 INSTALLATION INSTRUCTIONS Page 17 5. Place the shroud top onto unit sliding it down so the tabs on the back of the shroud top slide over the tabs flange on the unit. (Fig. 2) 6. Screw the shroud top to the shroud sides.
  • Page 18: Chimney

    PI29 INSTALLATION INSTRUCTIONS Page 18 CHIMNEY GENERAL CHIMNEY INSTALLATION Connect the venting system to the flue collar of the insert using three sheet metal screws. There are three predrilled holes in the flue collar. Place a bead of furnace cement around the flue collar connection to ensure the flue pipe is properly connected, secured and sealed.
  • Page 19: Operating Instructions

    FAN OPERATION Fans are an optional item for most Blaze King appliances. If fans are installed on your appliance, they should be turned off until the stove reaches normal operating temperatures. Approximately 30 minutes after a fire has been established within the appliance, the fan speed should match the thermostat control setting.
  • Page 20: Selecting Wood

    PI29 OPERATING INSTRUCTIONS Page 20 SELECTING WOOD THIS APPLIANCE IS DESIGNED TO BURN NATURAL WOOD ONLY. DO NOT BURN TREATED • WOOD, COAL, CHARCOAL, COLORED PAPER, CARDBOARD, SOLVENTS OR GARBAGE. HIGHER EFFICIENCIES AND LOWER EMISSIONS WILL GENERALLY RESULT WHEN BURNING •...
  • Page 21: Bypass

    PI29 OPERATING INSTRUCTIONS Page 21 BYPASS DOOR Your catalytic wood burning appliance is fitted with a bypass door which allows exhaust from the fire to temporarily bypass the catalytic combustor. The bypass door is located inside the dome of the firebox at the top of the appliance.
  • Page 22: Lighting The Fire

    Don’t be afraid to fill it completely if necessary. With the Blaze King thermostat, the wood will only burn at the rate set on the thermostat.
  • Page 23: Reloading Procedure

    PI29 OPERATING INSTRUCTIONS Page 23 RELOADING PROCEDURE WHEN PREPARING TO RELOAD, IF THE NEEDLE ON THE CATALYTIC THERMOMETER IS STILL IN THE ACTIVE ZONE, FOLLOW THE PROCEDURE BELOW; IF THE NEEDLE HAS DROPPED INTO THE INACTIVE ZONE, REFER BACK TO THE “LIGHTING THE FIRE” PROCEDURE ON THE PREVIOUS PAGE.
  • Page 24: Optimal Thermostat Setting

    OPERATING INSTRUCTIONS Page 24 OPTIMAL LOW BURN THERMOSTAT SETTING Your Blaze King appliance was tested and certified in accordance to the New Source Performace Standards for Residential Wood Heaters. During this test series, the low burn rate of the unit was determined by setting the thermostat knob to a position that yeilded the lowest burn rate achievable.
  • Page 25: Catalyst Monitoring

    If, after cleaning and reburning, your combustor is still not producing an ACTIVE reading you should contact your Blaze King dealer for a replacement combustor. Note - It is also possible that the catalytic thermometer itself may be functioning incorrectly. Before condemning the combustor, read CATALYTIC THERMOMETER in OPERATING INSTRUCTIONS.
  • Page 26: Catalytic Combustor, Troubleshooting

    Solution: Burn quality woods available in your area. If you decide the catalyst has been deactivated, replace combustor with a genuine Blaze King combustor (failure to do so will void your warranty). Severe Peeling 180-PI29 v1.08...
  • Page 27 PI29 CATALYST MONITORING Page 27 PROBLEM - CATALYST MASKING (The catalyst is coated with a layer of fly-ash or soot which prevents catalytic activity) Possible Cause: Accumulation of fly-ash Solution: Brush cooled combustor with a soft-bristled brush or vacuum lightly at least once per burning season. PROBLEM - THERMAL CRACKING Possible Cause: Normal operation, as long as the combustor remains intact.
  • Page 28: Catalytic Combustor, Replacement

    “CATALYST MONITORING”. If the combustor needs replacing then discontinue use of the appliance until the combustor is replaced. If the combustor must be examined or replaced contact your Blaze King dealer. 1. The removal of a Blaze King Catalytic combustor requires a small flat blade screwdriver or pocket knife.
  • Page 29 PI29 CATALYST MONITORING Page 29 4. Now that the combustor has been removed you’ll be able to see one stainless bypass retainer on each side. These can remain in place and do not need to be removed. These clips are not fixed in position and can fall into the firebox.
  • Page 30 The combustor supplied with this heater is either a 115-Z0444 ceramic combustor. Consult the catalytic combustor warranty also supplied with this wood heater. Warranty claims should be addressed to: in Canada in USA Blaze King Industries / Valley Comfort Systems Blaze King Industries Warranty Department, 1290 Commercial Way Warranty Department, 146A Street...
  • Page 31: Maintenance

    PI29 MAINTENANCE Page 31 RUN-AWAY OR CHIMNEY FIRE A CHIMNEY FIRE CAN PERMANENTLY DAMAGE YOUR CHIMNEY SYSTEM. THIS DAMAGE CAN ONLY BE REPAIRED BY REPLACING THE DAMAGED COMPONENT PARTS. CHIMNEY FIRE DAMAGE IS NOT COVERED BY THE LIMITED WARRANTY. CAUSES: 1.
  • Page 32: Ash Removal

    PI29 MAINTENANCE Page 32 CHIMNEY MAINTENANCE The most efficient method to sweep the chimney is using a hard brush. Brush downwards so soot and creosote residues will come off the inner surface and fall to the bottom of the chimney where they can be removed easily.
  • Page 33: Loading Door Gasket Inspection

    BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. If the door gasket is to be replaced, be sure you have Blaze King 7/8” fiber glass gasket ready to re- install, as well as high temperature adhesive. See your Blaze King dealer.
  • Page 34: Bypass Door Gasket Replacement

    BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. Will require THERMOSEAL® 1000SF high-temperature resistant cement and Blaze King 5/8” dense fiber glass gasket. See your Blaze King dealer. You will also require masking tape and combustor gasket as disassembly of the combustor will result in a damaged combustor gasket.
  • Page 35: Door Glass Gasket Inspection

    DOOR GLASS GASKET REPLACEMENT BLAZE KING RECOMMENDS YOUR DEALER PERFORM THIS TASK 1. You will require Blaze King glass gasket and Blaze King door gasket. Please see your Blaze King dealer. 2. Remove the old glass gasket. 3. Starting at the corner opposite of the “Blaze King”...
  • Page 36: Loading Door Tension Adjustment

    PI29 MAINTENANCE Page 36 LOADING DOOR TENSION ADJUSTMENT To tighten the seal, use a 9/16” wrench to loosen retainer nut on the outside and tighten nut on inside firebox to move latch catch in (see figure beside). Secure retainer nut and (repeat) paper test (see “LOADING DOOR GASKET INSPECTION”.
  • Page 37: Fan Assembly

    Holding the probe with a pair of pliers, loosen the bolt on the top of the dial. Turn the dial to align the pointer with the bottom of the “Inactive” zone, then retighten the bolt. NOTE: IF YOUR BLAZE KING IS EQUIPPED WITH FANS, TURN OFF FANS AND WAIT 10 MINUTES PRIOR TO READING CATALYTIC THERMOMETER INDICATOR. AIR MOVEMENT ACROSS THE TOP OF THE STOVE MAY PROVIDE FALSE READING.
  • Page 38: Troubleshooting

    Page 38 Your Blaze King is designed to allow a wide selection of heat output levels. If you begin to lose control of the amount of heat the stove is emitting, determine the cause early so that major problems may be avoided.
  • Page 39 INSPECTION” Excessive draft in the chimney. Measure draft with a Manometer. See “DRAFTS”. Consult your Blaze King dealer or a chimney sweep. Install a cap. Thermostat not operating properly. Consult your Blaze King dealer. Wood is too small.
  • Page 40 Consult your blaze King Dealer. By-pass door leaking or not closing completely. Inspect and clean area around by-pass doors. Adjust or replace gasket if necessary. Consult your Blaze King Dealer. PROBLEM: Spots of creosote accumulation in chimney or chimney connector. CAUSE SOLUTION Air leaks in chimney or chimney connector.
  • Page 41: Replacement Parts

    PI29 REPLACEMENT PARTS Page 41 exploded Part # Description view 150-0175-C Axial spider mount fan 145-0136 Rheostat with Off switch S.CAT29 Combustor S.Z4498 Replacement bypass retainers 4687.1 PI Flame sheld wing S.Z4551 Dome guard replacement kit S.0693 Latch catch S.Z0053 PI bypass cable repair kit S.Z4625 PI29 bypass lever assembly...
  • Page 42 PI29 REPLACEMENT PARTS Page 42 exploded Part # Description view 155-0186 Gasket 7/8” round black-6ft 155-0254-AS Gasket 1/8 x 3/4 W/PSA Spec-6ft 130-0246 Class ceramic 5mm PE S.Z4786.BK Door complete S.Z4044 Door handle assembly PE32/PI29 180-PI29 v1.08 September 27, 2021...
  • Page 43 PI29 REPLACEMENT PARTS Page 43 Brick Layout ITEM NO. PART NUMBER QTY. A Size Brick C Size Brick SI Size Brick T Size Brick U Size Brick W Size Brick WI Size Brick X Size Brick Z Size Brick 180-PI29 v1.08 September 27, 2021...
  • Page 44: Warranty

    Page 44 BLAZE KING WOOD LIMITED WARRANTY Blaze King and Valley Comfort’s respective brands extend the following warranty for wood fired appliances purchased from an authorized Blaze King / Valley Comfort dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.
  • Page 45 Blaze King is the manufacturer of the Blaze King line of heating products. At Blaze King, our commitment to the highest level of quality and customer service is the most important thing we do. Each Blaze King stove is built on a tradition of using only the finest materials and is backed by our limited warranty to the original purchaser.
  • Page 46 Blaze King The use of such products may nullify the Limited Warranty on this stove. If unsure as to the extent of this Limited Warranty, contact your authorized Blaze King dealer before installation.
  • Page 47 20%. 3rd year ----purchaser pays 40%. 4th year -----purchaser pays 60%. 5th year---- purchaser pays 80%. If a defect or problem is determined by Blaze King to be non warrantable, Blaze King is not liable for travel costs for service work. In the event of in-home repair work, the customer will pay any in-home travel fees or service charges required by the Authorized Dealer.
  • Page 48 PI29 NOTES Page 48 180-PI29 v1.08 September 27, 2021...
  • Page 49 PI29 NOTES Page 49 180-PI29 v1.08 September 27, 2021...
  • Page 50 PI29 NOTES Page 50 180-PI29 v1.08 September 27, 2021...
  • Page 51: Installer Notes

    PI29 INSTALLER NOTES Page 51 Installer: Please complete the following information Dealer Name & Address:________________________________________________________ ____________________________________________________________________________ Installer (print): _______________________________________________________________ Installer (sign): _______________________________________________________________ Phone #: ____________________________________________________________________ Date Installed:________________________________________________________________ Serial No.: ___________________________________________________________________ 180-PI29 v1.08 September 27, 2021...

Table of Contents