Summary of Contents for Blaze King Royal Guardian RGT-3001
Page 1
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL Blaze King Royal Guardian Owner's Installation Operation Manual Manufactured In Canada By: In U.S.A. By: Valley Comfort Systems Inc. B.K.I. Inc. 1290 Commercial Way 146 A Street Penticton, B.C.
Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL SAFETY NOTICE IF THE BLAZE KING, ROYAL GUARDIAN, MODEL RGT-3001, STOVE IS NOT PROPERLY INSTALLED, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY, FOLLOW THE INSTALLATION DIRECTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN YOUR AREA.
Page 3
OWNER'S INSTALLATION AND OPERATION MANUAL Dear Customer: Thank you for purchasing the Blaze King, Royal Guardian, Model RGT-3001, Wood burning Stove (hereafter referred to as "stove"). The Royal Guardian's contemporary elegance, complementary trim and decorator colors make it the first choice for improving your life style and enhancing the decor of your home.
Page 4
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL BLAZE KING LIMITED WOODSTOVE WARRANTY WARNING: TO VALIDATE THIS WARRANTY YOU MUST COMPLETE AND RETURN THE WARRANTY CARD WITHIN 20 DAYS OF THE DATE OF PURCHASE. WHAT THE WARRANTY COVERS: Blaze King Industries and/or Valley Comfort Systems Inc.
Page 5
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL BLAZE KING LIMITED WOODSTOVE WARRANTY RESPONSIBILITIES OF THE COMPANY: If the purchaser has complied with all of the terms and conditions of this warranty and If the purchaser has notified...
Page 6
Non combustible surfacing applied to the floor area underneath and extending in front, to the sides and to the rear of a heat producing appliance FLOOR PROTECTION MATERIAL For the RGT-3001, any non-combustible material or a Listed floor protector. FLUE The general term for a passage through which flue gasses pass form the combustion chamber to the outside air.
Page 7
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL SAFETY CHIMNEY FIRE In the event of a fire in the chimney: a. Adjust the thermostat to its lowest setting. b. Check the Loading Door to be sure it is tightly closed.
Page 8
OWNER'S INSTALLATION AND OPERATION MANUAL When selecting wood for the Model RGT-3001, it is preferable that you use seasoned wood. Dry, seasoned wood will burn cleaner and produce less creosote. Dry or small pieces of fuel will provide a hotter fire. Larger pieces can be used to provide a longer burn time.
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL SPECIFICATIONS FOR MODEL RGT-3001 Heat Output 39,000 Btu/hr. Wood Capacity (Approximate) White Oak ..................30 Lbs. Fir ....................20 Lbs. Recommended Wood Length ............16 In./40.6cm Total Weight with Firebrick (approximate) ......... 300 Lbs.
Page 10
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW STOVE This Blaze King Model RGT-3001 Wood stove is Listed by INTERTEK TESTING SERVICES, ONLY if: it is connected to a suitable masonry chimney, or a 6 Listed Residential Type and Building Heating Appliance Type Chimney System (hereafter referred to as Chimney) and minimum clearances to combustible (burnable) materials are observed.
Page 11
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL CHIMNEY HEIGHT AFFECTS DRAFT Tall chimneys usually provide a strong, dependable draft. The chimney should be kept warm to enhance the draft. This will also reduce creosote accumulation caused by smoke and condensation of water vapor. A buildup of creosote can reduce the draft and will become a potential fire hazard.
Page 12
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL Fig. Air Space Combustible Nail or screw anchor Wall Fig. Min. 24 Gauge Sheet Metal 1 inch non-combustible spacer such as stacked washers, small diameter pipe, tubing, electrical conduit.
Page 13
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL GENERAL INSTRUCTION FLOOR PROTECTOR The stove must be placed on a floor protector if the floor is wood or other combustible flooring. 1. Floor protection material: Any non-combustible material or Listed floor protector.
Page 14
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL CONNECTION TO A MASONRY CHIMNEY Should the stove be connected to a masonry chimney, the chimney should be examined for cracks, loose mortar, other signs of deterioration, and blockage. The stove should not be installed until it is determined that the chimney is safe for use.
Page 15
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL THIMBLE A thimble must be used when the connection from the stove is made through a combustible wall to a masonry chimney. There are several methods to use for connection through a combustible wall, two of which are illustrated in this manual. Local building authorities may be consulted or NFPA 211 and/or CAN-CSA B365 may be used for additional methods of chimney connection.
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL CONNECTION TO A METAL PREFABRICATED CHIMNEY CHIMNEY One of the following listed chimney connectors (with compatible listed chimney system) can be used with this stove. In the U.S. A.: Duravent Dura Plus HT, AmeriTec HS, Metalbestos HT or Security 103 HT. In Canada; you must use high temperature chimney meeting S629M requirements.
Page 17
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL REMEMBER: Follow the manufacturer's installation instructions and maintain the manufacturer's specified clearance distances.Install an attic insulation shield to maintain the specified clearance to insulation. Insulation in this air space will cause a heat buildup which may ignite the ceiling joists. This method of installation requires at a minimum a wall pass through device, a wall support package and insulated "T"...
Page 18
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL *REQUIRED TO ATTAIN ABOVE CLEARANCES 1. With 6" dia. 24/26 MSG Black/Blue steel chimney connector with Listed Residential Type and Building Heating Appliance type chimney. 2. With Side Shield with Fan Kit (P/N Z8301AA), and 6" dia. 24/26 MSG Black/Blue steel chimney connector with Listed Residential Type and Building Heating Appliance type chimney.
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL INSTALLATION INSTRUCTIONS A. RESIDENTIAL STANDARD AND REDUCED CLEARANCE CEILING EXIT INSTALLATION INSTRUCTIONS USING A PREFABRICATED CHIMNEY. Refer to Page 18, Fig. 21-23. Set floor protector and stove in location for marking holes in accordance with the label and figures of these instructions (page 18, Fig.
Page 20
The RGT-3001's flue collar accepts only 6" chimney connector. The small end of the connector fits into the collar to enable any water vapor which may form in the chimney to drain back into the stove.
Page 21
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL RESIDENTIAL STANDARD AND REDUCED CLEARANCE WALL EXIT WITH EXTERIOR MASONRY CHIMNEY Refer to Page 18, Fig. 24-25-26. Set floor protector and stove in location for marking holes in accordance with the label and figures of these instructions (Page 18, Fig.
Page 22
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL D. MOBILE HOME (FIG. 23,30), MOBILE HOME ALCOVE (FIG. 22), MOBILE HOME CORNER (FIG. 21), AND RESIDENTIAL ALCOVE (FIG. 22), INSTALLATIONS USING PREFABRICATED CHIMNEY. Refer to Page 18, Fig. 21, 22, 23, and Fig. 30 below.
Page 23
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL SIDE - SHIELD & FAN KIT P/N Z8301A Standard RGT Fan Assembly - Uppco, Model 50-T with insulated spade type connectors. Alternate RGT Fan Assembly - T30max Model 904-4999 with "push-in" connectors on the motor coil.
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL Rear Shield Wooden INSTALL SCREW INSTALL SCREW Handle NOTCH Control Assembly Firebox Mounting Holes For Rear Shield Side Shield Power Cord Fan Assembly with two 105 CFM INSTALL SCREW...
Page 25
Dry or small pieces of fuel will provide a hotter fire. Larger pieces can be used to provide a longer burn time. The wood for the Model RGT-3001 should be cut to lengths that are not more then 18" long; while 18" lengths will fit, 16" lengths are much preferred.
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL COMBUSTION AIR CONTROL OPTIMUM SETTING AFTER LOADING OR RELOADING 1.Position: Leave the combustion air-control in the Medium to High position for at least fifteen minutes before making further adjustments 2.Temperature Adjustments:...
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL DISPOSAL OF ASHES WARNING NEVER STORE HOT ASHES IN A GARAGE OR BASEMENT. HOT ASHES WILL GENERATE CARBON MONOXIDE AND/OR FLAMMABLE GASES. THESE GASES MAY CAUSE SUFFOCATION. Ashes should be placed in a metal container with a tight fitting lid. The closed container of ashes should be placed on a non combustible floor or on the ground, well away from all combustible materials, pending final disposal.
Page 28
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL MAINTENANCE AUTHORIZED SERVICE REPRESENTATIVE Your local BLAZE KING dealer is your authorized service representative. Should you have any problems with operating or maintaining your BLAZE KING Model 3001, contact him as soon as possible. The dealer will help you solve operating problems, provide replacement parts, and/or arrange warranty service repairs as required.
Page 29
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL LOADING DOOR GLASS REPLACEMENT Your BLAZE KING Model 3001 is equipped with a door which uses a strong, heat-resistant ceramic glass intended to withstand extremely high temperatures and tested for continuous use above 1200 degrees Fahrenheit.
TROUBLESHOOTING Your Blaze King, Model RGT-3001 is designed to allow a wide selection of heat output levels. If you begin to lose control of the amount of heat the stove is emitting, determine the problem early so that major problems can be avoided.
Page 31
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL PROBLEM: Too much heat CAUSE: SOLUTION: Thermostat not operating properly Consult your Blaze King Dealer Loading door gasket leaking, admitting Replace door gasket and/or adjust door excess air into firebox SEE Pg.
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL REPLACEMENT PARTS Listed below are some of the more commonly needed replacement parts. ITEM: PART#: NOTES: Thermostat Handle 0481BB Door Handle 0121AA Spray Paint Aerosol Can 13 oz. (specify color)
Page 33
Royal Guardian, Blaze King, LISTED SOLID FUEL ROOM HEATER Model RGT-3001 P/N 0194BB Also suitable for use in MOBILE HOME OWNER'S INSTALLATION AND OPERATION MANUAL MODEL: RGT 3001 Tested to: UL 1482/ULC S627 Report NO: 632-000500 (1/90) PREVENT HOUSE FIRES. Install and use only in accordance with manufacturer’s installation and operating instructions.
Page 34
Royal Guardian, Blaze King, Model RGT-3001 OWNER'S INSTALLATION AND OPERATION MANUAL INDEX OF TOPICS, TABLES & ILLUSTRATIONS Page: Topic: Introductory Letter Clearance Kits and Optional Accessories Warranty Definitions Safety Specifications Installation Preparation Reduced Wall Clearances General Installation Instructions Minimum Clearances to Combustible Surfaces Residential Standard/Reduced Roof Exit Installation Residential Reduced Clearance Wall Exit Inst.
Need help?
Do you have a question about the Royal Guardian RGT-3001 and is the answer not in the manual?
Questions and answers