Appliance Break-In; Heat Management - Majestic TRILLIANT25IN Installation Manual

Hide thumbs Also See for TRILLIANT25IN:
Table of Contents

Advertisement

K. Appliance Break-In
Follow the initial break-in procedure below to cure the
materials used to manufacture the fireplace and the
finishing materials around it.
• The fireplace should be run three to four hours
continuously on high flame.
• Turn the fireplace off and allow it to cool completely.
• Remove fixed glass assembly. See Section 9.A.
• Clean fixed glass assembly.
• Replace the fixed glass assembly and run continuously
on high an additional 12 hours.
Note: The IntelliFire Touch system has a safety feature
that automatically shuts down the fireplace after 9 hours
of continuous operation without receiving a command from
the remote control. If this occurs, restart the appliance.
NOTICE! Open windows for air circulation during fire-
place break-in.
• Some people may be sensitive to smoke and odors.
• Smoke detectors may activate.
Majestic • TRILLIANT25IN, TRILLIANT30IN, TRILLIANT35IN Installation Manual • 2571-980 Rev. B • 5/23
L. Heat Management
Heat Output
Heat Output is managed through the RC400 remote con-
trol that comes standard with the fireplace.
• Turn the appliance on and off.
• Adjust the height of the flame by varying the input using
the remote control.
• Adjust the fan speed.
For more information, see the instructions that accompany
the remote control.
NOTICE! Set the fan speed to high on the RC400 remote
control during the first three to four hours of break-in
operation. This break-in will ensure optimum speed control
of the fans during subsequent use.
53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trilliant30inTrilliant35in

Table of Contents