B. Wiring Requirements
IntelliFire Touch
Ignition System Wiring
®
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance power cord to a switched circuit.
Incorrect wiring will override IPI safety lockout.
• Refer to Figure 6.2, IntelliFire Touch (IPI) Wiring Diagram.
• This appliance is equipped with an IntelliFire control valve
which operates on a 6 volt system.
• Ensure the 6 volt transformer is plugged into the supplied
cord assembly to supply power to the unit OR install 4 AA
cell batteries (not included) into the battery pack before
use.
• Reset switch must be installed and in the "ON" position
for appliance to operate.
IFT-RC400
REMOTE
2550-013 (NG)
CONTROL
2550-014 (LP)
IFT-RC150
WIRELESS
WALL SWITCH
(OPTIONAL)
RF MODULE
2326-120
2166-302 (NG)
2166-303 (LP)
Figure 6.2 IntelliFire Touch Wiring Diagram
Majestic • TRILLIANT25IN, TRILLIANT30IN, TRILLIANT35IN Installation Manual • 2571-980 Rev. B • 5/23
30
FLAME
IGNITER
SENSE
TO POWER CORD 110-120 VAC
2326-191
S
I
BACK VIEW
2326-150
2326-130
TOP VIEW
FRONT VIEW
6 PIN
BLK
RED
SPLITTER
2187-198
BRN
BLK
2532-301
APPLIANCE
ON/OFF
CONTROL
(OPTIONAL)
BRN
BLK
WSK-21-W
TO POWER
CORD
110-120 VAC
2326-152
SIDE
VIEW
FAN 110-120 VAC
GFK-160A
BATTERY PACK
2326-142
* MODULE RESET SWITCH
2206-299
(LOCATED ON SURROUND)
* Reset switch must be installed
and in the "ON" position for
appliance to operate.
POWER CORD
2201-024
LIGHT WIRE
ASSEMBLY
2532-017
HALOGEN BULBS (X 2)
2201-150
NOT AN OPTION WITH 25 in. MODELS