Page 1
E3788-1 Rev A 5/4//2023 INSTALLATION & OPERATIONS INSTRUCTIONS ITH: Heated Models Engineering and technical data are subject to change without notice. FEDERAL INDUSTRIES 215 Federal Ave Belleville, WI 53508...
Weekly Cleaning ............................23 12.3 Cleaning The Optional Humidity Pan ......................24 (13) Service ................................26 (14) Sale & Disposal ..............................27 14.1 Owner Responsibility ........................... 27 (15) Troubleshooting ..............................28 (16) Service Parts ..............................30 E3788-1 Rev A - ITH...
(1) Introduction Thank you for purchasing a Federal Industries display case. This manual contains important instructions for installing and servicing your new display case. A repair parts list and wiring diagram are also included in the manual. Read all of these documents carefully before installing or servicing your case.
NOTICE: message, you may damage your case. The warning and safety labels shown throughout this manual are placed on your Federal Industries case at the factory. Follow all warning label instructions. If any warning or safety labels become lost or damaged, call our customer service department at (800) 356-4206 for replacements.
Ask for an immediate inspection of your concealed damaged item. Crating material must be retained to show the inspector from the truck line. E3788-1 Rev A - ITH...
See the rating plate for specific unit requirements. CAUTION Risk of Electric Shock. If the cord or plug becomes damaged, replace only with a cord and plug of the same type. E3788-1 Rev A - ITH...
After the unit is positioned and the leg levelers are turned out, the unit needs to be sealed to the floor for NSF approved installation. This is not required for models with casters or legs. E3788-1 Rev A - ITH...
Do not remove the screws holding trip strip to front panel. Slide the front panel down until it slides out of the top panel retainer lip at the top of the panel. Install panel in reverse order. E3788-1 Rev A - ITH...
2. Remove the (4) 8-32 top cover screws from top cover. 3. Slide the cover back from under the top glass trim. Note: there is a ground wire connected from case to the Top Cover. To prevent electrical shock Do NOT remove this wire. E3788-1 Rev A - ITH...
4. Align the mounting hole in top front corner of case with top front hole in end panel and attach with ¼-20 x .5LG thumb screw 5. Tighten all (4) thumb screws by hand. 6. Remove end panels in reverse order. E3788-1 Rev A - ITH...
2. Lift shelf bracket hook up behind back of shelf standard and rotate the shelf bracket downward until desired shelf bracket tab rests on front of shelf standard. 3. Bracket can be either flat 0 degrees 5 degree downward tilt as shown. E3788-1 Rev A - ITH...
Page 13
Damage LED light strip. 8. Manage desired cord lengths by pulling out cord from cord grommet or pushing cord back into cord grommet. NOTE: Cords always remain in case they are not removable. E3788-1 Rev A - ITH...
Page 14
5. Once shelf bracket is in place, rotate the shelf standard back to vertical position and reinstall top thumb screw and tighten. 6. Tighten lower thumb screw and install shelving as described in shelving installation. E3788-1 Rev A - ITH...
Page 15
(Similar to the letter B shape). The LED light has the same configuration. The shapes must align correctly when inserting LED plug into the LED light. E3788-1 Rev A - ITH...
1. Start with the outer door and lift the door upward until the bottom edge of door clears lower track and then swing the bottom of the door outward and down out of upper track. E3788-1 Rev A - ITH...
Page 17
2. After the outer door is removed repeat the procedure for the inner door. 3. Reverse this procedure for door reinstallation. Rear doors are not interchangeable. E3788-1 Rev A - ITH...
AIR TEMPERATURE POWER ON/OFF AIR HEATING SYSTEM. ADJUST INTERAL HUMIDITY LEVEL OF HUMIDITY (OPTIONAL) CASE. LIGHT ON INDICATES THAT WATER PAN IS DRY 10.1 Air Temperature Control Use the following procedure to adjust the control setpoints. E3788-1 Rev A - ITH...
Page 19
Temperatures are digitally controlled via factory settings 1-9. Setting “1” provides the coolest surface temperatures while setting “9” will provide the warmest. See table below for the temperature of each setting. CONTROL INTERAL CABINET SETTING TEMPERATURE 130°F 135°F 140°F 145°F 150°F 155°F 160°F 165°F 170°F E3788-1 Rev A - ITH...
4hrs prior to needing refilled. When the pan needs to be refilled the blue indicator light on the humidity control panel will light up. Water may be added prior to this, but it is not necessary. E3788-1 Rev A - ITH...
10.3 Typical Humidity Conditions The following table represents approximate humidity levels that the humidity package can generate at various control settings. Temperature Control Relative Humidity at Temperature [°F] Temperature [°C] Setting max highest setting 54.4 65.6 76.7 E3788-1 Rev A - ITH...
DO NOT USE the following packaging materials: Recycle Code Material Name Polyethylene terephthalate High-density polyethylene Polyvinyl chloride Low-density polyethylene Materials listed in the table above will not survive the high temperature conditions of this merchandiser. E3788-1 Rev A - ITH...
The case should be cleaned to this procedure before using the first time. NOTICE: Avoid splashing or soaking any electrical components with water to prevent electrical damage to the case. E3788-1 Rev A - ITH...
1. Locate the drain hose protruding from underneath the case. The rear panel will need to be removed if included. 2. Using a 2.5gal bucket or other container, open the drain valve and let the water drain completely into the bucket. 3. Close the drain valve to prevent any further flow. E3788-1 Rev A - ITH...
Page 25
8. For extreme scale buildup this procedure may need to be repeated, or full strength vinegar may be required. Other lime scale removal products may be used for this process, but anything used should be food safe. E3788-1 Rev A - ITH...
For warranty service requests and all technical support, including compressors and other service parts please contact: Phone: (833) 238-8168 Email: techservice@partstown.com Federal Industries has partnered with Parts Town for ALL Non-Warranty Part Identification, Pricing, Lead Times, Orders & Freight Quotes. Please contact Parts Town directly if you need parts: Website: PartsTown.com Email: CustomerService@PartsTown.com...
SALE & DISPOSAL 14.1 OWNER RESPONSIBILITY If you sell or give away your Federal Industries case you must make sure that all safety labels and the Installation-Service Manual are included with it. If you need replacement labels or manuals, Federal Industries will provide them free of charge. Contact the customer service department at Federal Industries at (800) 356-4206.
Temperature is too high Turn down control setpoint Check the control for errors and contact service Control Error Turn the main power switch to off to power down the unit Wait 10s, and power the unit back on E3788-1 Rev A - ITH...
Page 32
California Residents Only. WARNING This product can expose you to chemicals including chromium which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov E3788-1 Rev A - ITH...