Husqvarna AUTOMOWER 535 AWD Operator's Manual page 17

Hide thumbs Also See for AUTOMOWER 535 AWD:
Table of Contents

Advertisement

WARNING:
power supply. Condensed water can harm
the power supply and increase the risk of
electrical shock.
WARNING:
Install only to a residual-current device
(RCD) with a tripping current of maximum 30
mA when connecting the power supply to
the power outlet. Applicable to USA/Canada.
If power supply is installed outdoors: Risk of
Electric Shock. Install only to a covered
Class A GFCI receptacle (RCD) that has an
enclosure that is weatherproof with the
attachment plug cap inserted or removed.
CAUTION:
Do not make new holes in
the charging station plate.
CAUTION:
Do not put your feet on the
baseplate of the charging station.
WARNING:
and extension cable must be outside the
work area to avoid damage to the cables.
WARNING:
the low-voltage cable and the power supply
unit are clean and dry before you connect
them.
When connecting the power supply, only use a power
outlet that is connected to a residual-current device
(RCD).
1.
Read and understand the instructions about where
to put the charging station. Refer to
where to put the charging station on page 11 .
2.
Put the charging station in the selected area.
Note:
Do not attach the charging station with the
screws to the ground until the guide wire is
To install the guide wire on page
installed. Refer to
18 .
3.
Connect the low-voltage cable to the charging
station.
4.
Put the power supply at a minimum height of 30
cm / 12 in.
1427 - 006 - 25.11.2021
Do not encapsulate the
Risk of Electric Shock.
The power supply cable
Make sure that the plugs of
To examine
min 30 cm / 12"
5.
Connect the power supply cable to a 100-240V
power outlet.
Note:
When the charging station is connected, it
is possible to charge the product. Put the product
in the charging station while the boundary and
guide wires are being laid. Switch on the product to
start charging the product. Refer to
the product on page 26 . Do not continue with any
product settings before the installation is complete.
6.
Put the low-voltage cable in the ground with stakes
or bury the cable. Refer to
position with stakes on page 18 or To bury the
boundary wire or the guide wire on page 19 .
7.
Connect the wires to the charging station after the
installation of boundary wire and guide wire is
complete. Refer to
To install the boundary wire on
page 17 and To install the guide wire on page
18 .
8.
Attach the charging station to the ground with the
supplied screws after the guide wire is installed.
To install the guide wire on page 18 .
Refer to
3.5.3 To install the boundary wire
CAUTION:
Do not put remaining wire in
a coil. The coil causes interference with the
product.
1.
Put the boundary wire around all of the work area.
Start and complete the installation behind the
charging station.
2.
Open the connector and put the boundary wire in
the connector.
3.
Close the connector with a pair of pliers.
To switch on
To put the wire into
Installation - 17

Advertisement

Table of Contents
loading