Orion MLCD OLMU-4620S User Manual page 17

Table of Contents

Advertisement

4. Identify the IDs of all connected MLCD sets by clicking "INFO" button in Broadcast.
5. first, Identify the IDs of upper left corner MLCD set.
6. Set the IDs in Existing ID Menu indentified through the above 4) procedure. And then, set Group ID as 1 and Multi
ID as 1 in Changing ID Menu. And click "SET ID" button.
- 30 -
7. Identify the IDs on the right MLCD set of upper left corner MLCD set in the same way as the above 4) procedure.
8. Set the IDs in Existing ID Menu identified through the above 7) procedure. And then, Increase the number by 1 for
Multi ID in Changing ID Menu to set the ID order. and click "SET ID" button.
9. Repeat the above 7) and 8) procedures for the rest of displays in the same order as the number of the 10)
procedure's capture view.
10. After setting last MLCD set, ID setting status in MSCS Screen Configuration is as follows. It's different from
physical RS-232C cable connection.
ID 1
ID 2
ID 4
ID 5
ID 7
ID 8
- 31 -
ID 3
ID 6
ID 9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mlcd olmu-4650sMlcd olmu-5520sMlcd olmu-5550s

Table of Contents