FLOW CARTRIDGE REPLACEMENT

1. Observe disassembling sequence, as detailed in
section 14, steps 1 to 3.
2. Remove the flow control handle (right side) as detailed in
section 16 steps 1 to 4.
3. Slide off the stop ring.
4. Using a 17mm spanner or socket, undo the flow cartridge. The cartridge should now slide out of the
mixer's bore.
4. If necessary, replace the cartridge with a new one. Alternatively, if the cartridge is functioning correctly,
clean it thoroughly & reuse it.
5. With the cartridge located back in the mixer bore, screw the cartridge into the mixer body by
hand & then tighten with a spanner or socket. Ideally torque to 16Nm min to 18Nm max.
6. Refit the stop ring as illustrated above. Align the marked arrow on the stop ring to the front top corner
of the mixer body or use the marker on the square end cap as guidance.
7. Rotate the cartridge spindle fully clockwise until it stops.
8. Reverse the sequence to refit the handle, ensuring to refit the plastic drive insert onto the cartridge
spindle. Check & adjust the off position as shown in section 16. Ensure correct alignment of the handle.
17
min. 16 Nm
max. 18 Nm
29
A7216AA & A7221AA
Stop
ring
Stop
Align
ring