Siemens SIMOCRANE Operating Instructions Manual page 94

Energy storage system management v01.01
Table of Contents

Advertisement

Control and engineering
6.4 Controlling the power converters
Bit
Name
Bit 5
Spare
Bit 6
Spare
Bit 7
Acknowledge
[p2103.0]
Bit 8
Spare
Bit 9
Spare
Bit 10
MasterControl‐
Req [p854.0]
Bits 11-15 Spare
Table 6-17
DCP_Send.ControlWord2
CTW2
DCP_Receive.ControlWord2
Table 6-18
DCP_Send.Voltage_Setp
CTW3+4
DCP_Send.Voltage_Setp
Table 6-19
DCP_Send.CurrLimPos_Choke
CTW5+6
DCP_Send.CurrLimPos_Choke
Table 6-20
DCP_Send.CurrLimNeg_Choke
CTW7+8
DCP_Send.CurrLimNeg_Choke
Table 6-21
DCP_Send.CurrLimNeg_Choke
CTW9-16
DCP_Send.CurrLimNeg_Choke
92
Data type
Bool
Bool
Bool
Bool
Bool
Bool
Bool
Name
ControlWord2
Name
Voltage_Setp
[p54100]
Name
CurrLim‐
Pos_Choke
[p54141]
Name
CurrLim‐
Neg_Choke
[p54142]
Name
ControlWord9-16
Comment
-
-
Signal source for acknowledging faults
-
-
Control by PLC/no control by PLC
-
Data
Higher-level data
type
type
Word
DCP_Send
Data
Higher-level data
type
type
DWord
DCP_Send
Data
Higher-level data
type
type
DWord
DCP_Send
Data
Higher-level data
type
type
DWord
DCP_Send
Data
Higher-level data
type
type
Word
DCP_Send
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE
Comment
Spare
Comment
Signal source for the voltage con‐
troller setpoint
Comment
Signal source for the positive cur‐
rent limit of the voltage controller
Comment
Signal source for the negative
current limit of the voltage con‐
troller
Comment
Spare

Advertisement

Table of Contents
loading

Table of Contents