Bit 7
Cause
Remedy
Bit 8
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 9
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 10
Message class
Component
Response
Acknowledgement
Cause
Remedy
Bit 11
Message class
Component
Response
Acknowledgement
Cause
Remedy
SIMOCRANE Energy Storage System Management V01.01
Operating Instructions, 04/2023, A5E51573536B AE
Dynamic SOC power limitation charge direction active
•
Battery almost fully charged
•
SOC > SOCBatSysUpStart
Discharge the battery
Dynamic SOC power limitation discharge direction active
Warning
Dynamic SOC limitation
Limitation of the discharge power
Self-acknowledging
•
Battery almost fully discharged
•
SOC < SOCBatSysUpStart
Charge the battery
SOC Upper limit reached
Warning
Dynamic SOC limitation
The charge procedure is stopped
Self-acknowledging
•
Battery fully charged
•
SOC > SOCBatSysUpEnd
Discharge the battery
SOC Lower limit reached
Warning
Dynamic SOC limitation
The discharge procedure is stopped
Self-acknowledging
•
Battery fully discharged
•
SOC < SOCBatSysLowEnd
Charge the battery
Battery Voltage Low
Warning
Battery
None
Self-acknowledging
Battery voltage too low
Check the battery
Diagnostic system
7.2 Warnings
107