SINGlE ZONE – DUCTED TO HVAC SySTEM INSTAllATION
Using the dehumidifier in conjunction with the HVAC system is the optimum solution
for year-round, whole-home control . This installation is typically in basement or attic
locations, where air is pulled from the return duct, dehumidified, and discharged
to the supply duct . Additional configurations include only ducting the dehumidifier
outlet to the supply or ducting the inlet and outlet to the return duct . In the latter
case, the HVAC fan must be activated during dehumidification .
bASEMENT DUCTING & WIRING
fIGURE 9 – Single Zone – Ducted to HVAC System,
basement Installation
DEHUMIDIFIED AIR IS SUPPLIED
DOWNSTREAM FROM A-COIL TO
MINIMIZE EVAPORATION OFF A-COIL
HVAC / FURNACE
DEHUMIDIFIER
Wiring Notes:
• I f wiring to a Model 76 Control, see MODEL 76 EXTERNAL CONTROL section on page 19.
• I f wiring to a Model 8910 Home Comfort Control
THIRD-PARTY CONTROL section on page 21 .
AIR IS PULLED FROM
RETURN DUCT
90-1536
90-1537
or other Third-Party Control, see MODEL 8910 HOME COMFORT CONTROL
Required Components
Duct Work
18 – 22 AWG Wire
Optional Components
Condensate Pan & Normally Closed Float Switch
Grille
Model 76 Control
Model 8910 Home Comfort Control
Third-Party Control
fIGURE 10 – Single Zone – Ducted
to HVAC System, basement Wiring
THERMOSTAT
HVAC EQUIPMENT
R
C
G
W
Y
DEHUMIDIFIER
CONTROL BOARD
R
C
G
W
Y
OR
7