Appendix:

Appendix 1: Reference Sheet of Celsius and Fahrenheit

Conversion formula for Fahrenheit degree and Celsius degree: Tf=Tcx1.8+32
Set temperature
Fahrenheit
display
Fahrenheit
temperature
(℉)
61
62/63
64/65
66/67
68
Ambient temperature
Fahrenheit
display
Fahrenheit
temperature
(℉)
32/33
34/35
36
37/38
39/40
41/42
43/44
45
46/47
48/49
50/51
52/53
54

Appendix 2: Configuration of Connection Pipe

1.Standard length of connection pipe
● 5m, 7.5m, 8m.
2.Min length of connection pipeFor the unit with standard connection pipe of 5m, there is no limitation for themin length of
connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m.
3.Max length of connection pipe(More details please refer to the specifications)
4.The additional refrigerant oil and refrigerant charging required after prolonging connection pipe
● After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for
each additional 5m of connection pipe.
● The calculation method of additional refrigerant charging amount (on the basis of liquid pipe):
● Basing on the length of standard pipe, add refrigerant according to the requirement as shown in the table. The additional
refrigerant charging amount per meter is different according to the diameter of liquid pipe. See Sheet 2.
● Additional refrigerant charging amount = prolonged length of liquid pipe X additional refrigerant charging amount per meter
Diameter of connection pipe
Liquid pipe
Ф6 or Ф9.5
Ф12
Ф16
Ф19
Ф22.2
Note: The additional refrigerant charging amount in Sheet 2 is recommendedvalue, not compulsory.
Installation and Maintenance
Celsius (℃)
temperature
(℉)
60.8
16
62.6
17
64.4
18
66.2
19
68
20
Celsius ( ℃)
temperature
(℉)
32
0
33.8
1
35.6
2
37.4
3
39.2
4
41
5
42.8
6
44.6
7
46.4
8
48.2
9
50
10
51.8
11
53.6
12
Additional refrigerant charging amount for R32
Gas pipe
Ф6
Ф9.5 or Ф12
Ф16 or Ф19
Ф19 or Ф22.2
Ф25.4 or Ф31.8
/
/
Fahrenheit
display
Fahrenheit
Celsius (℃)
(℉)
(℉)
69/70
69.8
71/72
71.6
73/74
73.4
75/76
75.2
77
77
Fahrenheit
display
Fahrenheit
Celsius(℃)
(℉)
(℉)
55/56
55.4
57/58
57.2
59/60
59
61/62
60.8
63
62.6
64/65
64.4
66/67
66.2
68/69
68
70/71
69.8
72
71.6
73/74
73.4
75/76
75.2
77/78
77
Indoor unit throttl
Cooling only,cooling
Cooling only(g / m) Cooling and heating(g / m)
and heating(g / m)
16
40
80
136
200
280
Fahrenheit
display
Fahrenheit
temperature
(℉)
21
78/79
22
80/81
23
82/83
24
84/85
25
86
Fahrenheit
display
Fahrenheit
temperature
(℉)
13
79/80
14
81
15
82/83
16
84/85
17
86/87
18
88/89
19
90
20
91/92
21
93/94
22
95/96
23
97/98
24
99
25
Outdoor unit throttle
12
12
24
48
200
200
280
280
Celsius (℃)
(℉)
78.8
26
80.6
27
82.4
28
84.2
29
86
30
Celsius (℃)
(℉)
78.8
26
80.6
27
82.4
28
84.2
29
86
30
87.8
31
89.6
32
91.4
33
93.2
34
95
35
96.8
36
98.6
37
16
40
96
96
105

Advertisement

Table of Contents
loading

Table of Contents