P/N 0535974_R
APPLY GASKETS
(CONVERTIBLE)
IC2 / IC2X / IC3
Case bolting details begin on the
next page .
LEGEND:
A=1/2 X 1/2 INCH GASKET
B=NEUTRAL CURING SILICONE SEALANT
C=PIN-ALIGNMENT
D=COVER-HAND RAIL JOINT
E=BRACKET-FASCIA ALIGNMENT
IMPORTANT:
Do not pull cases together with bolts. Cases must be moved
together as close as possible Follow sequence balloons to
tighten bolts.
Merchandiser case joint & end gasket to be applied on only one
side of joint.
Merchandiser partition gasket to be applied on both sides of
joint.
Remove end shipping braces as described on Page 1-4
Cases must be leveled as described on Page 1-5
Removed any casters - if installed
Install case lineup from left to right
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
& ALIGNMENT CONE
& ALIGNMENT CONE
Remove shelves, display racks, pans & interior back panels at
the joining area
Insert gasket into case channels the entire length with no gaps
Do not stretch gasket, especially around corners
Do not butt gaskets, always overlap them
Remove paper backing after gasket has been applied
Perimeter gasket is required by NSF
Apply a continuous bead of neutral curing silicone sealant
Joints must be air tight to prevent formation of ice or condensation.
Minimum 1 1/2 in. Space
between case & wall
Medium Temperature
1-11