Download Print this page

SamplexPower Evolution EVO-RC Owner's Manual page 34

Remote control for inverter/ charger, 120/230 vac

Advertisement

SECTION 4 |
TABLE 4.2
CHARGING PROFILE FOR 4-STAGE ADAPTIVE CHARGING FOR EQUALIZATION
Options under
Srl
Programming
No.
Parameter
"EQUALIZE–4 STAGES"
1
EQUALIZE – 4 STAGES
0 = No (Default Setting)
1 = Yes
Parameter Setup
Charging Stages
1. Stage 1 – Bulk Stage (See Section 5.8.2 of the EVO
Manual for details):
Charge at constant current (CC) = the programmed value of
parameter "BULK CURRENT"
programming range & procedure, refer to Section 4.4.2.1)
Transition to Absorption Stage when voltage rises to the
set value for programming parameter "ABSORP VOLTAGE"
(Default value is 14.4V for EVO-2212/3012 and 28.8V for EVO-2224/4024.
For details of programming range & procedure, refer to Section 4.4.2.2)
2. Stage 2 - Absorption Stage (See Section 5.8.2 of the EVO
Owner's Manual for details):
Charge at constant voltage (CV) = the programmed value
for parameter "ABSORP VOLTAGE".
EVO-2212/3012 and 28.8V for EVO-2224/4024. For details of programming
range & procedure, refer to Section 4.4.2.2)
Adaptive Time Algorithm: Time in Absorption Stage is
computed automatically based on time in Bulk Stage
(See Section 5.8.2 of the EVO
Transition to Equalization Stage thereafter.
3. Stage 3 - Equalization Stage (See Section 5.8.2 of the EVO
Owner's Manual for details):
Charge at constant voltage (CV) = the programmed value of
parameter "EQUALIZE VOLTAGE".
EVO-2212 / EVO-3012 / EVO-2212E / EVO-3012E and 28.8V for EVO-2224
/ EVO-4024 / EVO-2224E / EVO-4024E). For details of programming range &
procedure, refer to Section 4.4.2.3.
Adaptive Time Algorithm: Time in Equalization Stage is
computed automatically based on time in Bulk Stage. (See
Section 5.8.2 of the EVO
Transition to Float Stage thereafter.
4. Stage 4 -
This stage will be the same as the last Stage of Charging Profile
from where Equalization was started. (For details, refer to
Table 5.2.1 under Section 5.8.2.4 of the EVO
for details):
Owner's
TM
(Default value is 40A. For details of
TM
(Default value is 14.4V for
Owner's Manual for details):
TM
(Default value is 14.4V for
Owner's Manual for details):
TM
Owner's Manual
TM
Battery Type
− Lead Acid: Flooded only
!
CAUTIONS!
1. Equalize Flooded Lead Acid Batteries.
Sealed AGM / Gel Cell types of batteries
are NOT equalized
2. Refer to Section 5.8.2 and Fig 5.2 of the
EVO
Owner's Manual.
TM
3. The Adaptive Charging Algorithm measures
the Bulk Stage Time (T0) to automatically
compute Absorption Stage Time (T1') and
Equalization Stage Time (T2). This algorithm
is fully effective only when there are no other
external DC loads being supplied by the
battery that may divert full or part of the BULK
CURRENT resulting in undesired increase in
Bulk Stage Time "(T0)" and consequently,
undesired increase of Absorption Stage Time
TM
(T1') and Equalization Stage Time (T2).
!
ATTENTIONS!
1. Égaliser les batteries au plomb inondées
seulement. Les batteries scellées de type
AGM / cellules au gel ne sont pas égalisées.
2. Reportez-vous à la section 5.8.2 et à la
figure 5.2 du manuel EVO
joint pour EVO-2212/3012/2224/4024 et
EVO-2212E/3012E/2224E/4024E.
3. L'algorithme de charge adaptative l'essentiel
des mesures de phase (T0) pour calculer
automatiquement l'étape d'Absorption
Temps (T1') et de la péréquation, le temps
(T2). Cet algorithme n'est pleinement efficace
que lorsqu'il n'y a pas d'autres charges
c.c. externe alimenté par la batterie qui
peut détourner tout ou partie de l'ACTUEL
EN VRAC résultant en une augmentation
indésirable en vrac temps Étape "(T0)" et
par conséquent, augmentation indésirable
de l'étape d'Absorption Temps (T1') et de la
péréquation le temps (T2).
d'utilisation ci-
TM

Advertisement

loading