Configuring the Ethernet Port Parameters
1. At the (config)# prompt, enter interface eth 0/1 to access the configuration
parameters for the Ethernet port located on the rear panel of the unit.
2. Enter ip address 10.10.20.7 255.255.255.0 to assign an IP address to the Ethernet
port using a 24-bit subnet mask.
If you are accessing the NetVanta via Telnet, once you change this IP address, you will
lose connection to the NetVanta. You must change the IP address of your PC before you
can proceed.
ADTRAN recommends that you set the Ethernet speed and duplex to match the switch or
hub it is plugged in to.
For example: (config-eth 0/1)#speed 10
3. Enter no shutdown to activate the interface to pass data.
4. Enter exit to exit the Ethernet interface commands and return to the global
configuration mode.
The NetVanta Network Interface Modules (NIMs) use a slot/port notation for interface
identification. All non-modular interfaces built into the base unit (e.g., the Ethernet port) are
identified using 0 as the slot number.
3
Beginning the E1 Network Interface Configuration
1. At the (config)# prompt, enter interface e1 1/1 to activate the interface
configuration mode for the E1 network interface.
2. If necessary (this is the default), enter clock source line to configure the unit to
recover clocking from the E1 network connection.
You should only need to change this setting for PPP, which will have one end set to line
(default) and the other end set to internal.
3. If two units are configured on a private E1 (PPP mode), set one unit to clock
source line and the other to clock source internal. For frame-relay, set both ends
to clock source line.