User Interface - Lincoln Electric FlexCut 125 CCC Operator's Manual

Table of Contents

Advertisement

®
FLEXCUT
125 CCC

USER INTERFACE

Mode Select Screen
Cutting
Press to Select
Choose between four available modes:
Cut – For cutting operations on a solid workpiece.
Mark – For discoloring or slight removal of material. Can
be used to add part numbers, bend lines, drill marks, or
many other surface modifications.
Grid – For cutting operations on a non-continuous
workpiece.
Gouge – For removing material from a workpiece
(removing a weld).
Active Mode Screen - See Figure B.4
Output Current
125
60
Output Gas Pressure
Active Mode Icon – The currently selected mode icon will be
displayed here. Return to the mode select screen to choose a new
mode.
Output Current – Turn the control knob to adjust the desired output
current. While cutting, the screen will display the actual cutting
current in Amps. Output current range is dependent on Mode
selected.
Output Gas Pressure – The output gas pressure is displayed on a
linear scale, with the center of the green range as the recommended
output gas pressure based on selected mode and torch length. Use
the regulator knob on the front of the machine to adjust the output
gas pressure, but do so only while gas is flowing. Hold the purge
button while pulling and turning the regulator knob to adjust the
pressure as desired.
Torch Length – The selected torch length will be displayed here. Be
sure the torch length matches the torch that is being used with the
machine. The torch length can be modified in the settings menu.
B-3
OPERATION
FIGURE B.4
A
Active Mode Icon
PSI
25ft
Torch Length