REGULATORY AGENCY REQUIREMENTS

8.0
8.1

Safety Certification

The Monitor does not inhibit customer from certifying product to following safety standards:
UL 1950/CAN/CSA C22.2 No. 950-95 Safety of Information Technology, including electrical
business equipment
UL 291Standard for Automated Teller Machine
EN 60950 Safety of Information Technology, including electrical business equipment.
8.2

CE Marking (Declaration according to ISO/IEC Guide 22 and EN45014)

The Monitor does not inhibit customer from conforming to the following EC Directives:
Council Directive 73/23/EEC and 93/68/EEC (Latest Amendment) on the harmonization of the laws
of the Member States relating to electrical equipment designed for use within certain voltage limits is
based on compliance with the following harmonized standards:
EN 60950 June 2000
EN 41003:1991
Council Directive 89/336/EEC, 92/31/EEC and 93/68/EEC (Latest Amendment) on the approximation
of the laws of the Member States relating to electromagnetic compatibility is based on compliance
with the following harmonized standards:
Electromagnetic Emissions
Electromagnetic Immunity
8.3

RFI Emission Certification

The Monitor is certified to the following emissions standards when installed in customer product
configuration:
FCC, Part 15, Paragraph 15.107(b) and 15.109(b), Class A RFI emissions standard.
EN 55022 Class A: 1994 ? Limits and measurements of radio interference characteristics of
information technology equipment.
IEC 1000 3-? 2 /1995; EN 61000-? 3 -? 2
IEC 1000 3-? 3 /1995; EN 61000-? 3 -? 3
8.4

System Transient Disturbance Requirements

The Monitor meets the following system transient disturbance requirements:
8.4.1
Title: Engineering Specification: 12.1-inch AMLCD Monitor
Document Number: 023-0284-00
EN 55022 Class A: 1994
EN 50082 part 1:1992

Electrostatic Discharge

The Monitor performs normally when subjected to static electricity discharges from
persons touching the external surfaces of the Monitor. Performance is verified by testing
according to EN 50082-1 (Ref IEC 801-2:1984) at severity level 3 (4 Kv contact discharge,
8 Kv air discharge).
Current Harmonic Tests
Voltage Fluctuation and Flicker Tests