Safety Precautions; Vrd (Voltage Reduction Device; Location And Ventilation; Stacking - Lincoln Electric VANTAGE 400-I Operator's Manual

Table of Contents

Advertisement

VANTAGE
®
400-I

SAFETY PRECAUTIONS

WARNING
Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer's
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.
-----------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and ground
• Always wear dry insulating gloves.
-----------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or
vent exhaust outside.
-----------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or
guards off.
• Stop engine before servicing.
• Keep away from moving parts.
-----------------------------------------------------------
See additional warning information at
front of this operator's manual.
Only qualified personnel should install,

VRD (VOLTAGE REDUCTION DEVICE)

The VRD feature provides additional safety in the CC-Stick mode
especially in an environment with a higher risk of electric shock such
as wet areas and hot humid sweaty conditions.
The VRD reduces the OCV (Open Circuit Voltage) at the welding output
terminals while not welding to less than 13V DC when the resistance
of the output circuit is above 200Ω (ohms).
The VRD requires that the welding cable connections be kept in good
electrical condition because poor connections will contribute to poor
starting. Having good electrical connections also limits the possibility
of other safety issues such as heat-generated damage, burns and
fires.
The machine is shipped with the VRD switch in the "Off" position. To
turn it "On" or "Off".
• Turn the engine "Off".
• Disconnect the negative battery cable.
• Lower the control panel by removing 4 front panel
screws. (See Figure A.1)
• Place the VRD switch in the "On" or "Off" position. (See Figure
A.1)
With the VRD switch in the "On" position, the VRD lights are enabled.
FIGURE A.1
REMOVE 4 FRONT PANEL
SCREWS TO ACCESS
(VRD) SWITCH

LOCATION AND VENTILATION

The welder should be located to provide an unrestricted flow of
clean, cool air to the cooling air inlets and to avoid restricting the
cooling air outlets. Also, locate the welder so that the engine
exhaust fumes are properly vented to an outside area.

STACKING

VANTAGE
®
400-I machines cannot be stacked.

ANGLE OF OPERATION

Engines are designed to run in the level condition which is where
the optimum performance is achieved. The maximum angle of
continuous operation is 20 degrees in all directions, 30 degrees
Intermittent (less than 10 minutes continuous) in all directions. If
the engine is to be operated at an angle, provisions must be
made for checking and maintaining the oil level at the normal
(FULL) oil capacity in the crankcase.
When operating the welder at an angle, the effective fuel capaci-
ty will be slightly less than the amount specified.
A-3
INSTALLATION
(VRD)-VOLTAGE REDUCTION DEVICE
SWITCH IS LOCATED IN THIS AREA.