TOP MOUNTED ICEMAKER REQUIREMENTS

1
Location - Avoid placing the dispenser and/or ice
machine near heat sources such as radiators, ov-
ens, refrigeration equipment and direct sunlight.
2
Clearances - Six inch (15.2 cm) clearance on all
sides of the icemaker is needed.
3
Front of icemaker to be flush with front of dis-
penser- The front of the icemaker should be flush
with the front of the dispenser, as shown in the draw-
1
6"
(15.2 cm)
NOTE: For full information about icemaker installation, including plumbing lines connections and
electrical requirements, see the icemaker installation manual.

Ice Flow Restrictor

All manuals and user guides at all-guides.com
INSTALLATION
4
5
6" (15.2 cm)
clearance
2
for cuber
cuber
6"
(15.2 cm)
ICE FLOW RESTRICTOR
For all Servend MD/MDH Series dispensers an ice flow
restrictor is available. This ice flow restrictor decreases
the amount of ice allowed to enter the ice chute by block-
ing a small area at the entrance of the dispenser chute.
This in turn restricts the flow of ice that is dispensed in to
your cup.
Please refer to the instructions included in kit #5013822
for more information on how to install.
ing above. Because the icemaker is flush with the
front of the dispenser, some icemakers may over-
hang at the back of the dispenser.
Drains - A separate drain line is required for the ice
machine, in addition to a drain line for the ice/bev-
erage dispenser.
MD Series dispensers require an adapter kit to
install a top-mounted icemaker. Contact your lo-
cal Servend distributor for the correct adapter kit.
6" (15.2 cm)
5
3
3
4
4
Installation and Service Manual
6" (15.2 cm)
13