OPERATING INSTRUCTIONS
To operate the inverter turn the inverters On/Off switch to ON. The inverter will beep
momentarily while it carries out a brief self-analysis before supplying power to the AC
socket. To turn off, turn the inverter On/Off switch to OFF.
Note: Ensure the RCD Switch is down, the red indicator will be showing.
Note: Where possible the inverter will automatically select 240V AC mains power
rather than DC battery power during operation.
To help prevent the inverter being overloaded:
1. Ensure appliances are turned off before turning the inverter on.
2. If multiple appliances are being run, turn on one at a time.
ECO MODE
Eco mode is designed to help reduce power consumption extending battery run time
(1000mA to 10mA). ECO mode can be activated via pressing ECO button located
on the front of the unit. Four different settings are available depending on the users
application/requirements.

ECO MODE SETTINGS:

oFF: ECO mode will not activate.
1 Hr: After no load being drawn from the inverter for a period of 1 hour the inverter
will go into ECO mode.
3 Hr: After no load being drawn from the inverter for a period of 3 hours the inverter
will go into ECO mode.
on:
After no load being drawn from the inverter for a period of 30 seconds the
inverter will go into ECO mode.
To select a setting press the ECO button until the required status appears on the
L.E.D screen located on the front of the unit.
If ECO mode is set to 1Hr, 3Hr or ON the inverter is waiting for a load less than
0.5W before it starts timing. To wake up the inverter from ECO mode (Power save
mode), press any of the buttons on the front panel or the remote or alternatively
connect a device that draws more than 5-8W to the inverter. Whilst the inverter
is in the ECO/Power save mode it will automatically check if a device is connected
to the inverter every 5 seconds.