•Induction System
Climate Control Series
2022209100, August 2018
Step 2)
While the compressor is running, screw the spring loaded adjust-
ment screw in (clockwise) to increase the amount of air pressure
required to open the switch and stop the unit.
Screw the spring loaded adjustment screw out (counterclock-wise) to de-
crease the amount of air pressure required to open the switch and stop the unit.
The maximum discharge pressure for a Climate Control Series
compressor is 90 PSIG Do not set the pressure switch to exceed this
limit.
Electric power always exists inside the pressure switch whenever
the compressor package is connected to a power supply. Be careful
not to touch any electrical leads when setting the pres sure switch.
Never exceed the designed pressure for the system or overload the
motor beyond its Maximum Amp Draw.
* Full Load Amps x Service Factor = Maximum Amp Draw
* Full Load Amps (FLA) & Service Factor can be found on the motor nameplate.
Never assume a compressor is safe to work on just because it is not
operating. It may be in the automatic stand-by mode and may re-
start any time. Follow all safety precautions outlined in SECTION
5, •Stopping For Maintenance.
Air Intake
A clean, cool and dry air supply is essential to the satisfactory op eration of your
Quincy air compressor. The standard air filter that the compressor is equipped
with when leaving the factory is of suffi cient size and design to meet normal
requirements, when properly ser viced, in accordance with the maintenance
section of this manual.
If, however, the compressor is to be installed in a location where consid-
erable dust, dirt and other contaminants are prevalent, con sult your local
Quincy distributor for advice and optional filters. A condensate trap must be
installed as close as possible to the inlet filter if, as a result of installation or
environmental conditions, there is any risk of moisture forming in the inlet
piping. It is the user's responsibility to provide adequate filtration for those
conditions. Oil bath filters are not to be used. Warranty will be void if a
failure is determined to be caused by inadequate filtration.
Remote Inlet Filters
Depending on the size of the compressor and the size and construc tion of the
room in which the unit operates, the air inlet may have to be located outside
of the room. If it is necessary to remotely install the air filter, make the inlet
piping as short and direct as possible. Remotely installed air filters can lead
to vibrations in the inlet pip ing. These vibrations can be minimized by adding
a pulsation dampener in the inlet piping between the remote inlet filter(s)
and the compressor.