Fig. 3-13 Recommended Air Tank Inspection Intervals
Climate Control Series
2022209100, August 2018
Visually
Wall Thickness
Inspect
Head
Shell
.094
.106
Yearly
.109
.111
Yearly
.109
.135
Yearly
.109
.111
Yearly
.109
.135
Yearly
.131
.133
Yearly
.131
.162
Yearly
.163
.199
Yearly
.163
.199
Yearly
.163
.199
Yearly
Air Tank Inspection
Hydrostatically
Quincy Compressor recommends that all
Inspect
air tanks be inspected at scheduled inter-
vals. Refer to Fig. 3-13 Recommended
10 Years
Air Tank Inspection Intervals for
10 Years
relative information. Measure tank wall
10 Years
thickness at several locations, including
10 Years
the lowest point where condensation can
accumulate.
10 Years
10 Years
Refer to federal, state or provincial,
10 Years
or local codes for mandatory air tank
10 Years
maintenance information.
10 Years
10 Years