5.2 PLC External I/O Contact Details

IN
distribution
S/S
24V
Start button
X0
On
Two-hand switch
X1
Trigger
(rising edge)
Reset button
X2
Reset
(rising edge)
Light Curtain
X3
Safety
X4
Recipe 0
X5
Recipe 1
DIP Switches
X6
Recipe 2
X7
Recipe 3
Power
reference
24V
(hold type)
(NC)
16
Power
OUT
distribution
reference
Y0
Ready
Indicator
Y1
Waiting
Indicator
Y2
Alarm
Indicator
(red)
Y3
OK/NG
Indicator
(green)
UP
24V
24V
ZP
24G
24G