Victron energy MPPT 150/35 Manual page 9

Smartsolar charge controller
Hide thumbs Also See for MPPT 150/35:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
3.5 Configuration of the controller
Fully programmable charge algorithm (see the software page on
our website) and eight preprogrammed charge algorithms,
selectable with a rotary switch:
Pos
Suggested battery
Gel Victron long life (OPzV)
0
Gel exide A600 (OPzV)
Gel MK
Gel Victron deep discharge
Gel Exide A200
1
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
Default setting
Gel Victron deep discharge
2
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
AGM spiral cell
3
Stationary tubular plate
(OPzS)
Rolls AGM
PzS tubular plate traction
4
batteries or
OPzS batteries
PzS tubular plate traction
5
batteries or
OPzS batteries
PzS tubular plate traction
6
batteries or
OPzS batteries
Lithium Iron Phosphate
7
(LiFePo
) batteries
4
Note 1: divide all values by two in case of a 12V system and multiply by two
in case of a 48V system.
Note 2: equalize normally off, see sect. 3.8 to activate.
(do not equalize VRLA Gel and AGM batteries)
Note 3: any setting change performed with Bluetooth or via VE.Direct will
override the rotary switch setting. Turning the rotary switch will override prior
settings made with Bluetooth or VE.Direct.
Type
Absorption
Float
V
V
28,2
27,6
28,6
27,6
28,8
27,6
29,4
27,6
29,8
27,6
30,2
27,6
30,6
27,6
28,4
27,0
Equalize
dV/dT
V
mV/°C
@%I
nom
31,8
-32
@8%
32,2
-32
@8%
32,4
-32
@8%
33,0
-32
@8%
33,4
-32
@25%
33,8
-32
@25%
34,2
-32
@25%
n.a.
0
7

Advertisement

Table of Contents
loading

Table of Contents