Jung FRWM200 Operating Manual page 64

Smoke alarm device with radio link
Hide thumbs Also See for FRWM200:
Table of Contents

Advertisement

Available languages

Available languages

(5) Complete the shared radio group with
one device of the shared radio group.
f Observe chapter 6.3 „Finalising radio
group" on page 62.
(6) Perform similar actions for other
sub-groups.
5 Shared radio group is in operation.
f To verify, perform the connection
test (see chapter 6.7 „Shared group
connecting test" on page 64).
6.6 Group connection test
You can check the correct connection of
a group (radio groups or a shared radio
group) as follows:
(1) Press and hold testing / stop button
of any device of the group for
approx. 12 seconds.
Short acoustic signal,
single device
Short acoustic signal,
single device
64
Operating Manual: FRWM200 - Smoke Alarm Device with Radio Link
(2) Release testing / stop button.
Short acoustic signal,
single device
5 Successful connection test of the
single device and the radio group.
When a device within the radio
group is defective, the device
triggering the alarm and all
available devices sound an alarm
signal. The defective device stays
silent and can thus be identified
(see chapter 12 „Alarm and alert
tones" on page 76).
6.7 Shared group connecting test
You can check the correct connection
of a radio group to a shared radio group
as follows:
Only possible with subgroup
devices.
(1) Press and hold testing / stop button
of any device of the subgroup
pressed for approx. 60 seconds.
EN

Advertisement

Table of Contents
loading

Table of Contents