Jung FRWM200 Operating Manual page 52

Smoke alarm device with radio link
Hide thumbs Also See for FRWM200:
Table of Contents

Advertisement

Available languages

Available languages

The use of smoke alarm devices is gov-
erned by DIN 14676.
Minimum equipment
Bedrooms
Children's bedroom
Guest room
Corridors that serve as escape routes
Stairwells of apartment buildings
Optimal equipment
All residential and hobby rooms
Heating and work spaces
Office or workroom
Cellar
Attic
Conditional equipment
In kitchens, smoke alarm devices must
only be installed when false alarms
(e.g., caused by steam) are excluded
Not recommended
Bathrooms are excluded from the in-
stallation of smoke alarm devices due
to the high development of steam
52
Operating Manual: FRWM200 - Smoke Alarm Device with Radio Link
Exception: bathrooms with
washing machines and cabinets
4.1 Area to be monitored
Use a device if at least one of the follow-
ing applies:
Monitoring area less than 60 m
and ceiling height of less than 6 m
Ceiling panels (height lower
than 20 cm) with joists (ceiling
surface less than 36 m
Use additional equipment if at least one
of the following applies:
Monitoring area greater than 60 m
Ceiling height greater than 6 m
High partial walls
Separating pieces of furniture
Platform / gallery (area greater than
16 m², at least 2 m long and wide)
Ceiling panels (height greater
than 20 cm) with joists (ceiling
surface more than 36 m
,
2
)
2
2
)
2
EN

Advertisement

Table of Contents
loading

Table of Contents