8.1.6.3 WALL MOUNTING

Installation procedure
1 Wall mounting procedure
2 Water piping connection
3 Drain pipes connection
4 Refrigerant piping connection
5 Power and transmission wiring connection 6 Cover assembly
7 Test and check
Wall mounting procedure
Make sure the wall has adequate strength to hang weight of the indoor unit.
1. Fix the wall support (factory-supplied accessory) to the wall.
Drill 3 holes according to the circular hole position of the wall support as shown below, and the hole diameter shall meet
the requirements of M8 expansion bolts.
Using 3 M8 expansion bolts Fix the wall support to the wall. Make sure that the wall support is completely levelled.
2. Hang the indoor unit on the wall support, using the square hole on the back panel of indoor unit. At least two persons are
required in order to lift the unit because of its weight.
The square
hole
15
65
65
63
Unit: mm
Complete hanging
Installation
W
Expansion bolt

Advertisement