10.7.3 Solar panels antiFreezing protection
The solar panels may be frozen in the winter. It is necessary to circulate hot water to the solar panels to prevent them from
being frozen . when hot water temperature of solar panels [Tsolar] is too low , the solar pump begins operating in order to
transfer the heat to the solar panels through heat exchanger.
● Solar pump ON when all of the following conditions are met.
① [Tsolar] is less than [Tsolar_antiFreezing]-2 °C.
② [TDHW] is higher than [Tsolar] +6 °C.
● Solar pump OFF when any of the following conditions is fulfilled.
① [Tsolar] is higher than [Tsolar_antiFreezing].
② [TDHW] is less than [Tsolar] +2 °C.
NOTE:
1. Overheat protection is available when [Solar_s] set as [solar sensor].
259