Structure Of Hi-Therma Indoor Unit - Hisense Hi-Therma Series Service Handbook

Air-to-water heat pump, split/integra outdoor unit, split indoor unit, integra indoor unit, monobloc
Hide thumbs Also See for Hi-Therma Series:
Table of Contents

Advertisement

6.2.2 Structure of Hi-Therma Indoor Unit

Side view
Charge port
Mark
1
Auxiliary Electric Heater(AEH)
2
Air purge valve
3
Electric Heater Thermostat
4
Safety valve
5
Drain pipe for safety valve
6
Expansion Vessel Connection Pipe
7
Heat Exchanger Water Outlet Pipe
8
Electric Heater Water Outlet Pipe
9
Expansion vessel
10
Water pump
11
Outlet Water Thermistor(Tow)
12
Inlet Water Thermistor(Tiw)
13
Liquid Refrigerant Pipe Thermistor(TL)
14
Water Inlet
15
Water Outlet
16
Refrigerant Liquid Pipe
Front view
Bottom view
Part name
47
Mark
Part name
17
Refrigerant Gas Pipe
18
Drain Pan
19
Gas Refrigerant Pipe Thermistor(Tg)
20
Water Pressure Sensor(Pw)
21
Plate Heat Exchanger
22
Outlet HP Water Thermistor(TowHP)
23
Electrical Box
24
Back Panel
25
Side Panel
26
Front Panel
27
Controller
28
Wall Support
29
Shut-off Valve with Filter
30
Shut-off Valve
31
Adapter Tube
General dimensions