Drilling the Piping Hole in the Wall
Follow all piping clearance recommendations.
1. Using a 2-17/32 inch hole core drill bit, drill a hole at either the right or left side of the wall
mounting, pre-chosen following installation guidelines and application needs.
• The slant of the hole must be 3/16" to 5/16" from level with the slant being upward on the
indoor unit side and downward on the outdoor unit side.
2. Finish off the newly drilled hole as shown with bushing and sleeve covering to prevent dam-
age to the insulation and piping.
Mounting the Installation Plate to Wall
Follow the procedure below and general best practices when mount-
ing the indoor unit's installation plate to a wall.
1. The wall mounted indoor unit is shipped with the installation plate
attached to its back. To remove, unscrew the one (1) screw that
holds the installation plate to the back of the indoor unit.
2. Align the centerline using a leveling tool. Measure the wall and
mark the centerline.
3. Attach the installation plate to the wall following the measure-
ments and marks. Use the type "A" screws that are factory-sup-
plied with the plate. If mounting the unit on a concrete wall, use
field-supplied anchor bolts.
4. Observe all rear piping clearances when drilling into the wall.
• When choosing a location for the wall mount plate, be sure to take
into consideration routing of wiring for power outlets within the wall.
• Use caution when drilling holes through the walls for the purposes
of piping connections. Power wiring can cause serious bodily injury
or death.
Select location carefully. Unit must be anchored to a strong wall to
prevent unnecessary vibration.
Removing the Indoor Unit Bottom Panel
To access the indoor unit piping port connections, and to make the indoor unit installation
procedure easier, open the front panel, and remove the bottom panel removed first.
1. Fully open the front panel. The control panel can be accessed on the bottom right side
of the front of the indoor unit.
2. Pull the screw cap(s) at the bottom of the indoor unit.
3. Unscrew the five (5) screws (depending on the indoor unit model) at the bottom of the
chassis panel.
4. Remove the bottom panel, being careful not to scratch the main horizontal vane.
Set aside the bottom panel to re-install after all procedures are complete.
GENERAL INSTALLATION GUIDELINES
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.
Figure 14: Drilling Piping Hole.
Core Drill
Figure 12: Extended Piping Wall Mount Indoor Unit Installation Plate.
Installation Plate
Chassis
Hook
Figure 13: Extended Piping Wall Mount Indoor Unit Installation Plate
Dimensions.
Installation Plate
30-
11/16
Ø2-5/8
1-3/4
4-3/4
Unit: Inch
Left rear piping
Figure 15: Removing the Bottom Panel from
Indoor Unit.

Indoor Unit Mounting

WALL
Indoor
Outdoor
Bushing
Sleeve
Type "A" Screws
Ø2-5/8
1-3/4
4-3/8
Right rear piping
Cover
13-
3/16
19