Mounting Installation Plate to Wall (090HSV4, 120HSV4, 180HSV4)
Follow the procedure and best practices below when mounting the
indoor unit's plate to a wall.
Procedure
1. Before installation of the plate, confirm the position the screw
types (A or B) between chassis and installation plate.
2. Mount the installation plate horizontally by aligning the centerline
using a leveling tool.
3. Use provided screws when mounting the plating.
• If mounting the unit on concrete wall, use field supplied anchor
bolts.
4. Observe the left and right rear piping clearance when drilling into
the wall, as shown in Figure 11 (090HSV4, 120HSV4) and Figure
12 (180HSV4).
Select location carefully. Unit should be anchored to a strong wall to pre-
vent unnecessary vibration.
• When choosing a location for the wall mount plate, be sure to take
into consideration routing of wiring for power outlets within the wall.
Contacting wiring can cause serious bodily injury or death.
• Use caution when drilling holes through the walls for the purposes
of piping connections. Power wiring can cause serious bodily injury
or death.
Refer to "Drilling Piping Hole in the Wall" on page 16 as
you follow procedure to install plate.
Figure 11: Installation Plate - 090HSV4, 120HSV4
Installation Plate
Place a level on raised tab
Unit Outline
17-13/32
Ø2-19/32
Left
rear piping
4-
27/32
6-
29/32
Unit: Inch
GENERAL INSTALLATION GUIDELINES
090HSV4, 120HSV4
17-13/32
Ø2-19/32
Right
rear piping
3- 24/32
8-
17/32
Due to our policy of continuous product innovation, some specifications may change without notification.
©LG Electronics U.S.A., Inc., Englewood Cliffs, NJ. All rights reserved. "LG" is a registered trademark of LG Corp.

Mounting of Indoor Unit Installation Plate

Figure 9: Installation Plate Screws - 090HSV4, 120HSV4
Place a level on raised tab
Unit
A Type : 442
Outline
B Type : 434
Ø65
Installation Plate
A Type B Type
123
175
Figure 10: Installation Plate Screws - 180HSV4
Figure 12: Installation Plate - 180HSV4
Place a level on raised tab
Unit Outline
18-3/32
Ø2-19/32
Installation Plate
Measuring Tape
Left rear
piping
2 -11/ 1 6
4-3/32
Measuring Tape
A Type : 442
B Type : 439
Ø65
Ø65
A Type : 95
217
B Type : 170
(Unit : mm)
A-Type
B-Type
180HSV4
22-13/32
Ø2-19/32
Right rear
piping
2-3/16
8-3/32
Hanger