SPOOL GUN SETUP

1. Switch on the machine, select the MIG function with the MIG/MMA selector switch.
2. Select Spool Gun using the Standard/Spool Gun selector switch.
3. Connect the Spool Gun to the Euro Mig torch connection socket on the front panel, and tighten it. Connect the Spool Gun control cable to the
receptacle and tighten it.
4. Insert the earth cable plug into the Negative socket on the front of the machine and tighten it.
5. Connect Gas Line to Gas Regulator and connect the gas regulator to the Gas Cylinder.
6. Connect the Weld power cable to the Positive socket.
(2) Set Spool Gun / Standard selector to Spool Gun.
4 (-)
3
(7) Push the cover release button to unlock the wire
feed /spool cover.
5
1
6 (+)
(8) Place a spool of wire onto the Spool holder. Note:
the spool retaining nut is Left Hand thread, turn it
clockwise to undo it.