Noise Emission Information - Technifor XF510Cr Operating And Maintenance Manual

Integrable marking head numerically controlled
Table of Contents

Advertisement

Noise emission of the machine
A

2. Noise emission information

The values given below represent the noise emitted by the machine during marking. When the machine is in use,
the values mentioned are independent from the total noise level to which the operator is exposed, since the actual
noise level will vary depending on the operator's environment.
Position
1
2
3
When marking resonant parts (metallic, hollow, thin), wear hearing protection for
sound levels L
Similar results for XF510Cr/Dr machines.
Ref. DCD01/3074 - XF510Cr-Sr-Dr_en_C
L
Aeq
(L
= "equivalent" average sound
Aeq
level measured using the A-
weighting)
78 dB(A)
74 dB(A)
71 dB(A)
> 85 dB(A) or L
Aeq
L
pc
(L
= peak acoustic pressure level)
pc
88 dB(C)
85.5 dB(C)
80 dB(C)
> 137 dB(C).