F - Noise Emission Of The Machine; Test Code; Measurement Method; Definition Of The Microphone Position - Technifor XF510Cr Operating And Maintenance Manual

Integrable marking head numerically controlled
Table of Contents

Advertisement

Noise emission of the machine
F

1. Test code

Measurement method

The measurements were taken according to the regulations of standard ISO 12001: 1996.
Measurement equipment used:
• 01dB - Stell integrated sonometer, SIP 95 S, # 20394
• Cal 01 calibrator, # 40141
Material used for marking:
• type XF510Sr machine mounted on a column stand + magnetic plate clamp
• one electronic command unit: UC500
The marking is carried out using a NA1 stylus on a steel plate with dimensions of 110 mm (4.331 in) x 110 mm
(4.331 in) x 3 mm (0.118 in) clamped to a base support. A new plate is used for each test.

Definition of the microphone position

The microphone is placed at:
• position 1: 0.5 m (1.64 ft) facing the machine and 1.2 m (3.937 ft) from the ground
• position 2: 0.5 m (1.64 ft) facing the machine and 1.6 m (5.249 ft) from the ground
• Position 3: 1 m (3.281 ft) facing the machine and 1.6 m (5.249 ft) from the ground

Test conditions

• Marking speed: 100%
• Movement speed: 100%
• Compressed air system pressure: 3 Bar (43.511 PSI)
• Marking quality: 100%
• Stroke force: 100%
• Marking of 1 line(s) of 10 character(s) 5 mm (0.197 in) high
Ref. DCD01/3074 - XF510Cr-Sr-Dr_en_C
F
29/31

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xf510srXf510dr

Table of Contents