Effort Exerted On The Mounting Plate - Technifor XF510Cr Operating And Maintenance Manual

Integrable marking head numerically controlled
Table of Contents

Advertisement

Effort exerted on the mounting plate

• XF510Cr
The effort exerted on the mechanics during the marking procedure is transferred to the plate.
Approximative forces and couplings exerted on the head's fastening, brought to point A, without taking into
account the forces and couplings due to the machine's weight, depending on the integration's position (for this
calculation: consider the center of gravity as being at the center of the machine's volume)
Efforts given for an operating pressure of 6 Bar (87.023 PSI) (when pressure varies, apply the rule of
proportionality)
Fx = Fy (daN)
Fz (daN)
Cy max (daN.m)
Cy min (daN.m)
Cx max (daN.m)
Cx min (daN.m)
Cz (daN.m)
Ref. DCD01/3074 - XF510Cr-Sr-Dr_en_C
Installation
A
Stylus
NA0
NA1
± 8.0
± 18.8
8.0
18.8
1.5
3.7
-1.2
-2.8
2.1
4.9
-0.7
-1.6
± 0.9
± 2.1
NA1 LG 100
N2
± 18.8
± 36.9
18.8
36.9
4.5
6.6
-3.7
-5.0
5.8
9.1
-2.4
-2.4
± 2.1
± 4.1
C
NA2
± 36.9
36.9
7.2
-5.6
9.7
-3.0
± 4.1
16/31