Every Year - Technifor XF510Cr Operating And Maintenance Manual

Integrable marking head numerically controlled
Table of Contents

Advertisement

Preventive maintenance
D
A

3. Every year

Have the marking head serviced by Technifor.
This operation includes:
• complete dismantling of the machine
• cleaning of the mechanical elements
• replacement of the rails and guide bearings
• replacement of the solenoid valves
• verification of the condition of the motors and the belt
• reassembly and adjustment of mechanical elements
• debugging of the head in an enclosure
• marking tests
This maintenance list was established based on a marking frequency of:
• 520 000 cycles per year (7 800 000 characters per year)
• 15 characters 3 mm (0.118 in) high per cycle
2
2
• 8 continuous working hours on steel strength 50 DaN/mm
(72518.869 lb/in
)
During servicing of the marking head, Technifor can provide identical rental equipment so that production is not
interrupted.
Contact your distributor to schedule an appointment for servicing. This "tune-up" does not take a long time.
Ref. DCD01/3074 - XF510Cr-Sr-Dr_en_C