User instructions Wall hung RSF gas fired condensing regular boiler GREENSTAR Ri For central heating systems These appliances are for use with : Natural Gas or L.P.G. (Cat. II 2H 3P type C13, C33 & C53) Model GC Number Natural Gas 12Ri 41-406-41 15Ri...
Page 2
There is also the reassurance of our parts and labour guarantee - backed up by Worcester Total Cover, an optional complete maintenance scheme to keep your appliance operating at peak condition and efficiency.
Contents Contents Key to symbols and safety instructions 4 Glossary 19 Key to symbols 4 Safety precautions 4 General information 5 Energy efficiency 5 Servicing 5 Benchmark standard 5 User caution 5 Controls 6 Operating the boiler 7 3.1.1 Switching the boiler ON/Off 7 3.1.2 Setting the boiler flow temperature 7 3.1.3...
Key to symbols and safety instructions A step in an action sequence Key to symbols and safety instructions A sequence of defined actions or steps carried out in order to complete a task. Key to symbols ▶ Action ▶ Next action Warnings ▶...
The service record will show a potential purchaser Worcester, Bosch Group accepts no liability arising from any that the heating system has received regular professional such actions. This does not affect your statutory rights.
Controls Controls 6720813340-01.1Wo Fig. 1 Controls 1 Mains power ON/OFF knob 5 Maximum flow temperature position 2 Indicator/Diagnostic light “MAINS ON/OFF” (Blue) 6 Boiler reset position 3 Minimum flow temperature position 7 Burner ON indicator light (Green) 4 Flow temperature control knob Table 2 Greenstar Ri - 6 720 813 340 (2014/09)
Controls Operating the boiler 3.1.1 Switching the boiler ON/Off ▶ Turn the “MAINS POWER” knob to 1 to switch ON the boiler. ▶ Turn the “MAINS POWER” knob to 0 to switch OFF the boiler. 6720813340-02.1Wo Fig. 2 Switch ON/OFF boiler. The boiler frost protection function will not work if the mains power knob is switch to OFF.
Controls 3.1.3 Turning the central heating off during the summer Do not switch the boiler off at the mains power switch or mains fused spur. ▶ To turn your central heating off during warm periods: ▶ Set the programmer to OFF –...
System pressure System pressure Open vented heating systems If the boiler is fitted to an open vented system, that is a system with a header tank, the pressure will be maintained automatically. Sealed heating systems If this boiler is fitted to a sealed heating system, the system will be pre-pressurised. Your installer will have fitted a pressure gauge and filling loop so that the system can be monitored and adjusted as necessary.
System pressure External filling loop NOTICE: External filling loops ▶ If the filling loop does not look like the one shown in the figure below or you cannot find your filling loop, contact your installer. ▶ To comply with Water Authority regulations you must disconnect the external filling loop after re- pressurisation.
Service Clearances Service Clearances Your installer will have provided adequate space around the boiler for safety and servicing access. CAUTION: Restricted space. The boiler may overheat. ▶ Do not restrict this space with the addition of cupboards, shelves etc. next to the boiler. 2 0 m m m * * 6 0 0 m...
If your Greenstar gas-fired appliance should fail to operate correctly or requires servicing, please contact the Worcester, Bosch Group Appointments Team (see rear cover for details).
In the event that the boiler stops functioning or does not perform as expected, you can carry out a few simple checks. These checks are some of the most common causes of apparent faults and are listed in the table below. Should the problem persist or other alert codes are displayed, then it will be necessary to contact Worcester, Bosch Group. Problem...
A reset fault condition will exist If the electrical power to the boiler has been interrupted. Reset the boiler as described above. Fig. 7 Reset button and mains light If the fault remains and cannot be cleared by resetting the boiler, contact Worcester, Bosch Group for assistance. Greenstar Ri - 6 720 813 340 (2014/09)
Wait two to three minutes for the boiler to restart. ▶ If the boiler does not restart, contact Worcester, Bosch Group appointments team on: 0330 123 9339. ▶ Contact your installer in order to find a permanent solution to the problem.
In the case of a suspected fault, refer to the fault finding section of this guide. In the event of a boiler fault or breakdown please contact Worcester, Bosch Group appointments team on 0330 123 9339. Your advisor will arrange for an engineer to call with the minimum of delay; under normal circumstances this will be from 1 - 3 working days (excluding weekends) for priority breakdown situations (no hot water and/or heating).
Tips on energy saving Tips on energy saving Heating economically The appliance provides a high level of comfort whilst keeping gas consumption low and so minimising the environmental impact. The gas supply to the appliance‘s burner is regulated according to the demand for heat. The appliance operates with a low flame if the demand for heat reduces.
Your Greenstar boiler carries a guarantee against faulty material or manufacture subject to Terms and Conditions. To read the full Terms & Conditions please visit us on-line at www.worcester-bosch.co.uk/guarantee. The Guarantee Registration form is available on this same page and can be completed and submitted electronically.
Page 19
Glossary Glossary Central heating systems All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the bottom then it should be bled by releasing air through the bleed screw at the top of the radiator. Ask your installer to show you how this is done.
Page 20
0330 123 9119 TRAINING: 0330 123 0166 SALES: 0330 123 9669 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR4 9SW. Tel. 0330 123 9559 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 6 720 813 340 (2014/09)