Benchmark RD 532 combi Installation And Servicing page 10

Table of Contents

Advertisement

Details of the appliance
Condensate analysis, mg/l
Ammonium
1.2
≤ 0.01
Lead
≤ 0.001
Cadmium
≤ 0.005
Chromium
Halogenated
≤ 0.002
hydrocarbons
Hydrocarbons
0.015
Copper
0.028
Table 3
Flue system
HORIZONTAL 100 mm – Standard FLUE SYSTEM
Overall Diameter of Duct
Flue Terminal / Duct
Assembly Length
Extension Duct Length
Table 4
HORIZONTAL 125 mm FLUE SYSTEM
Overall Diameter of
Duct
Flue Terminal / Duct
Assembly
Table 5
VERTICAL 100 mm FLUE SYSTEM
Overall Diameter of Duct
Flue Terminal / Duct
Assembly
Table 6
VERTICAL 125 mm FLUE SYSTEM
Overall Diameter of Duct
Flue Terminal / Duct
Assembly
Table 7
Elbow - 90 ° Equivalent length 2 m
Bend - 45 ° Equivalent length 1m
10
Nickel
0.15
≤ 0.0001
Mercury
Sulphate
≤ 0.015
Zinc
≤ 0.01
Tin
≤ 0.001
Vanadium
pH-value
mm
100
mm
600
Max.
4 m
mm
1000
mm
125
Max. 13 m
(including
turret)
mm
1030
mm
100
Max.
13.7m
(Excl.
mm
1140
Terminal)
mm
125
Max. 5m
(Excl.
mm
1365
Terminal)
Gas supply
Total length of gas supply pipe
(metres)
1
3
6
Gas discharge rate (m
8.7
5.8
18.0
12.0
4.8
Table 8
Domestic water performance
Domestic
Water Flow
Rate l/min
Maximum Mains pressure
Minimum Mains pressure
Table 9
Pipe diameter
(mm)
9
3
/h)
4.6
22
9.4
28
Temperature
Rise
30 °C
Temperature
Rise
35 °C
Temperature
Rise
40 °C
bar
bar
6 720 611 451 GB (03.11)
15.6
13.3
11.7
10.0
0.2

Advertisement