Panasonic SE4D Series Instruction Manual page 83

Light curtain type 4
Table of Contents

Advertisement

Common specifications
Type
Item
Model No.
Detecting capability
(Min. sensing object)
Effective aperture angle (EAA) ±2.5 degree or less [for sensing range exceeding 3m (Required by IEC 61496-2, ANSI/UL 61496-2)]
Supply voltage
<For PNP output>
• Maximum source current: 200mA
• Applied voltage: Same as supply voltage
Control output
• Residual voltage: 2.5V or less (source current 200mA,
(OSSD 1 / 2)
• Leakage current: 0.1mA or less
• Maximum load capacity: 0 22µF(No load to maximum
• Load wiring resistance: 3Ω or less
Operation mode
ON when all beams are received, OFF when one or more beams are interrupted (Note 1, 2)
(Output opera ion)
Protection circu t (Short-circuit)
Response time
<For PNP output>
• Maximum source current: 60mA
Auxiliary output
• Applied voltage: Same as supply voltage
(Non-safety output)
• Residual voltage: 2.5V or less (source current 60mA,
Operation mode
(Output opera ion)
Protection circu t (Short-circuit)
Protection
Degree of pollution
Ambient temperature
Ambient humidity
Ambient illuminance
Opera ing altitude
Voltage wi hstandability
1,000V AC for one min. (between all supply terminals connected together and enclosure)
Insulation resistance 20MΩ or more with 500V DC mega (between all supply terminals connected together and enclosure)
Vibration resistance
Shock resistance
SFF (Safe failure fraction)
HFT (Hardware fault tolerance)
Subsystem·Type
Mission time
Emitting element
Connection method
Material
Enclosure: Aluminum, Upper / lower case: SPCC, Sensing surface: PC / Polyester resin, Cap: PBT
Accessory
EN 61496-1 (Type 4), EN 55011, EN 61000-6-2, EN 50178, EN ISO 13849-1 (Category 4,PLe)
IEC 61496-1/2 (Type 4) ISO 13849-1 (Category 4, PLe), IEC 61508-1 to 7 (SIL3)
Applicable standard
JIS B 9704-1/2 (Type 4), JIS B 9705-1 (Category 4), JIS C 0508 (SIL3)
ANSI/UL 61496-1/2 (Type 4), UL 1998 (Class 2)
Notes: 1) The beam channel is not turned OFF during muting even if it is blocked.
2) In case the blanking function is valid, the operation mode is changed.
3) The intermediate supporting bracket (SE9Z-SED-2) is enclosed with the following devices. The quantity
of the enclosed bracket differs depending on the device as follows:
1 set: 40 to 56 beam channels
2 sets: 64 to 80 beam channels
3 sets: 88 to 96 beam channels
PNP open-collector / NPN open-collector transistor (switching type)
(between the control output and +V)
when using 15m length cable)
(Including power supply OFF condition)
output current)
(OFF when fault occurs in the sensor to the synchronization single error, too)
In normal operation...OFF response: 14ms or less, ON response: 80 to 90ms
PNP open-collector transistor / NPN open-collector transistor (switching type)
(between the auxiliary output and +V)
when using 15m length cable)
When OSSDs are ON: OFF, when OSSDs are OFF: ON (factory setting)
[Changeable by using the handy controller (SE9Z-HC) (optional).]
-10 to +55°C(No dew condensation ot icing allowed), Storage:-25 to +70°C
Incadescent lamp: 3,500 ℓ x or less at the light-receiving surface
10 to 55Hz frequency, 0.75mm amplitude in X, Y, and Z directions for two hours each
2
300m/s
acceleration (Approx. 30G) in X, Y and Z directions for three times each
Infrared LED (Peak emission wavelength: 870nm)
SE9Z-SED-2 (Intermediate supporting bracket): (Note 3)
20mm pitch type
SE4D-H
ø25mm opaque object
24V DC ± 10 % Ripple P-P10% or less
<For NPN output>
• Maximum sink current: 200mA
• Applied voltage: Same as supply voltage
• Residual voltage: 2.5V or less (sink current 200mA,
• Leakage current: 0.1mA or less
• Maximum load capacity: 0.22µF(No load to maximum
• Load wiring resistance: 3Ω or less
Incorporated
<For NPN output>
• Maximum sink current: 60mA
• Applied voltage: Same as supply voltage
• Residual voltage: 2.5V or less (sink current 60mA,
Incorporated
IP65 and IP67(IEC60529)
3
30 to 85%RH, Strage: 30 to 95%RH
2,000m or less
99%
1
Type B (IEC 61508-2)
20 years
Connection with connectors
SE9Z-TR25 (Test rod): 1
(between the control output and 0V)
when using 15m length cable)
(Including power supply OFF condi ion)
output current)
(between the auxiliary output and 0V)
when using 15m length cable)
82