5.7

Access to head internal part

The burner leaves the factory set for opening to the right, there-
fore maintaining the pin 1)(Fig. 16) in the housing.
A Remove the screws 2);
B open the burner to a maximum of 100-150 mm by rotating
around the hinge and release the cables of the probe 5) and
electrode 6);
C fully open the burner as in Fig. 16;
D undo the screw 3) with pressure test point.
E Release the head by lifting it from its housing 4), then take out
the combustion head.
Installation
5
20110637
4
2
23
GB
2
3
2
1
6
2
Fig. 16
20107195