Omron F3SJ-E N25 Series User Manual page 49

Safety light curtain
Hide thumbs Also See for F3SJ-E N25 Series:
Table of Contents

Advertisement

To enable the muting function, D3 and d2 must satisfy formulas (3) and (4), respectively.
This distance must prevent the muting function from being enabled by a person passing through the
muting sensors. Also, install the F3SJ-B and muting sensors so that each workpiece passes through
all muting sensors before the next workpiece arrives at the first muting sensor.
Workpiece
Moving direction
<Wiring diagram>
Using a photoelectric switch as a muting sensor
B1
A1
F3SJ-B
* Two-wire type muting sensor cannot be used.
Workpiece
B2
A1, B1, A2, B2 :
Retro-reflective
photoelectric switch
- NPN Output
- ON when Interrupted
A2
System Configuration and Functions
Workpiece
Workpiece
Moving direction
Using an N.O. contact type switch as a muting sensor
A1
A2
B1
B2
A1, A2, B1, B2:
N.O. contact type switch
+24 VDC
Power
supply
0 V
F3SJ-E/B
User's Manual
E
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sj-b n25 series

Table of Contents