Table of Contents

Advertisement

Quick Links

®
Instruments
Oscilloscope
HM 303-5
SERVICE-MANUAL
HM303-5

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HM 303-5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Hameg HM 303-5

  • Page 1 ® Instruments Oscilloscope HM 303-5 SERVICE-MANUAL HM303-5...
  • Page 2: Table Of Contents

    Table of contents Service Manual Circuit Diagrams Adjustment Procedure HM303- Y-Preamplifier CH I (YP-Board) ........4 Y-Preamplifier CH II (YP-Board) ......... 5 Y-Intermediate Amplifier and Trigger Amplifier (YP-Board) ..............6 YPA-Board (Bottom side) .......... 7 YPA-Board (Top side) ..........8 XY-Board (X-Amplifier) ..........
  • Page 3 Subject to change without notice...
  • Page 4 Leistungsverbrauch. Gegen magnetische Einwirkungen von außen ist die Strahlröhre des HM303 mit Mumetall abgeschirmt. Prüfkreis liegt einpolig an Masse (Schutzleiter) Alles in allem hat HAMEG mit diesem Gerät wieder einmal Maßstäbe Verschiedenes gesetzt, die entsprechend seinem Preis-/Leistungs-Standard einfach beispiellos sind.
  • Page 5: Y-Preamplifier Ch I (Yp-Board)

    Y-Preamplifier CH I (YP-Board) Subject to change without notice...
  • Page 6: Y-Preamplifier Ch Ii (Yp-Board)

    Y-Preamplifier CH II (YP-Board) Subject to change without notice...
  • Page 7: Y-Intermediate Amplifier And Trigger Amplifier (Yp-Board)

    Y-Intermediate Amplifier and Trigger Amplifier (YP-Board) Subject to change without notice...
  • Page 8: Ypa-Board (Bottom Side)

    YPA-Board (Bottom side) Subject to change without notice...
  • Page 9: Ypa-Board (Top Side)

    YPA-Board (Top side) Subject to change without notice...
  • Page 10: Xy-Board (X-Amplifier)

    XY- Amplifier Subject to change without notice...
  • Page 11: Xy-Board (Y-Amplifier)

    XY Board (Y Amplifier) Subject to change without notice...
  • Page 12: Xy-Board (Top Side)

    XY Board (Top and Bottom side) Subject to change without notice...
  • Page 13: Sync.-Amplifier

    Sync.- Amplifier Subject to change without notice...
  • Page 14: Timebase

    Timebase Subject to change without notice...
  • Page 15: Sweep-Generator

    Sweep- Generator Subject to change without notice...
  • Page 16: Tb-Board

    TB Board Subject to change without notice...
  • Page 17: Crt-Board

    CRT- Board Subject to change without notice...
  • Page 18: Crt-Board (Top And Bottom Side)

    CRT Board (Top and Bottom side) Subject to change without notice...
  • Page 19: Power Supply (Ps-Board)

    Power Supply (PS-Board) Subject to change without notice...
  • Page 20 PS-Board (Top side) Subject to change without notice...
  • Page 21: Ps-Board (Bottom Side)

    PS Board (Bottom side) Subject to change without notice...
  • Page 22: Component Tester, Calibrator

    Component tester, Calibrator Subject to change without notice...
  • Page 23: Cct-Board (Top And Bottom Side)

    CCT Board (Top and Bottom side) Subject to change without notice...
  • Page 24: Front-Controlboard

    Front- control board Subject to change without notice...
  • Page 25: Front-Controlboard (Top And Bottom Side)

    Front Control board (Top and Bottomside) Subject to change without notice...
  • Page 26: Adjustment Procedure

    Adjustment Procedure Subject to change without notice...
  • Page 27 WARNINGS contained therein. • should only be performed by suitable qualified and experienced service personnel, or should be referred to one of the HAMEG companies listed on the rear cover of the manual. Test Instruments required: Scope Tester HZ60-2.
  • Page 28 Table of Contents R1008: +141 Volt supply................29 R1016: +12 Volt supply................29 VR7000: Trace Rotation Check..............29 R1004 : CRT minimum intensity..............29 R712RT maximum intensity................ 29 R712: Mean Y-plate Potential Channel I............. 29 R714: Mean Y-plate Potential Channel II.
  • Page 29 Front panel PS-Board YPA-Board PS-Board XY-Board Pin 2 Pin 4 Subject to change without notice...
  • Page 30: R1008: +141 Volt Supply

    R1008: +141 Volt supply. WARNING: To avoid damage use a fully insulated screwdriver! Locate and identify R1008 (1) on PS-Board (screened section). Locate 8 pole checkpoint socket on XY-Board and identify pin 2. Adjust R1008 (1) for exactly +141Volts (± 0.1 Volt). R1016: +12 Volt supply.
  • Page 31 YPA-Board PS-Board Subject to change without notice...
  • Page 32: Rv6021 : Astigmatism Correction

    RV6021 : Astigmatism correction. Locate and identify RV6021 (8) on CRT-Board. Connect a 1MHz squarewave signal with 25mVpp at 50Ω (HZ22) to input CHI. Set time base to 0.1µs/div. Adjust FOCUS control for optimum sharpness. Adjust RV6021 (8) until leading edge and top of signal have equal sharpness. Recheck range of FOCUS control.
  • Page 33: R139: 100Hz Squarewave 5Mv/Div Ch I

    YPA-Board (13) R139: 100Hz Squarewave 5mV/div CH I. Locate and identify R139 (13) in CH I section of the YPA-Board. Connect a 25mV/100Hz squarewave signal via 50Ω cable and 50Ω through terminator to input channel I. Set time base to 2ms/div. Check that DC input coupling is selected.
  • Page 34: R134: 100Hz Squarewave 1Mv/Div Adjustment Ch I

    (14) R134: 100Hz Squarewave 1mV/div Adjustment CH I. Locate and identify R134 (14) in CH I section of the YPA-Board. Connect a 5mV/100Hz squarewave signal via 50Ω cable and 50Ω through terminator to input channel I. Press Yx5 channel I (in!) for 1mV/div. Set time base to 2ms/div.
  • Page 35 XY-Board YPA-Board Subject to change without notice...
  • Page 36: Rv2005 (A), Rv2006 (C), Cv2000 (D) And Cv2001 (B): Y-Final Amplifier

    (21) RV2005 (A), RV2006 (C), CV2000 (D) and CV2001 (B): Y-Final Amplifier. Connect a 1MHz squarewave signal of 25mV via 50Ω cable and 50Ω through termination to input CH I. Check that DC input coupling is selected. Set time base to 0.2µs/div. Locate and identify the adjustment points RV2005 (21A), RV2006 (21B), CV2000 (21C) and CV2001 (21D) on XY-Board.
  • Page 37 YPA-Board XY-Board TB-Board Subject to change without notice...
  • Page 38: R663: Addition/Offset

    (25) R663: ADDition/Offset. Press DUAL pushbutton (in!). Locate and identify R663 (25) on YPA-Board. Set input coupling CH I and II to GD. Move both baselines with Y-POS. I and II controls to the horizontal center line of the graticule. Release DUAL pushbutton (out!).
  • Page 39 TB-Board YPA-Board XY-Board Subject to change without notice...
  • Page 40: Rv2234: X-Magnification X10

    (31) RV2234: X-Magnification x10. Locate and identify RV2234 (31) on XY-Board. Press pushbutton X-Mag. x10. Set time base to 50µs/div. Set time mark generator to f= 20kHz and connect signal to CH I input. Set X-POS control to mechanical center. Using X-POS control, move the visible time mark to the first left graticule line.
  • Page 41 XY-Board CT-Board Pin 1 Pin 14 Subject to change without notice...
  • Page 42: Rv2301 (A), 4322 (B): Component Tester Y-Position And Tilt

    (36) RV2301 (A), 4322 (B): Component Tester Y-Position and Tilt. Release all pushbuttons (out!). Press COMPONENT TESTER pushbutton (in!). Locate and identify RV2301 (36A) on XY-Board. Adjust RV2301 (36A) to shift the approx. 8 div. horizontal component tester trace to the horizontal center of the CRT graticule.
  • Page 43: Video Trigger Check

    Set input coupling CH I to GD. Remove signal cable from input CH I and connect it to TRIG.INP. socket. Do not change generator settings. Now the Trigger-LED should be ON again. (41) Video Trigger Check. Set CH I input coupling switch to DC. Connect video signal with positiv sync.
  • Page 44: Interface Commands

    ® Germany HAMEG GmbH Instruments Industriestraße 6 63533 Mainhausen Tel. (06182) 8909 - 0 Telefax (06182) 8909 - 30 Oscilloscopes E-mail: sales@hameg.de HAMEG Service Multimeters Kelsterbacher Str. 15-19 60528 FRANKFURT am Main Tel. (069) 67805 - 24 Telefax (069) 67805 - 31...