  • Page 1 Instructions Biaxial Mixer BIAX 35/45 Keep this manual within immediate reach of the machine Translation of the original instructions -en Englisch Version 1.5-18...
  • Page 2 BIAX 35/45 Collomix GmbH Version 1.5-18...
  • Page 3: Table Of Contents

    Collomix GmbH BIAX 35/45 Contents Layout Drawings ........................4 Machine components Operating and display components About this document ......................6 Pictograms and symbols For your safety ........................7 General Safety Information Intended Use Foreseeable Misuse Qualifications of operating personnel Safety-relevant components 3.5.1 Closed housing...
  • Page 4: Layout Drawings

    BIAX 35/45 Collomix GmbH Layout Drawings Machine components Machine components 1. Machine legs 5. Manual door release 2. Sliding door 8. Control panel CSE 3. Main switch and main fuse 7. Lower clamping plate 4. Emergency Stop 8. Locking lever...
  • Page 5: Operating And Display Components

    Collomix GmbH BIAX 35/45 Operating and display components Button for DOOR • OPEN door • OPEN the mixing unit Button E • STOP – stop mixing cycle prematurely • ACKNOWLEDGE messages Button I • Mixing cycle I (Factory settings 1:00 Minute)
  • Page 6: About This Document

    Safety information is in Chapter 2. You find information on warnings in the introduction of Chapters and before instructions. Collomix GmbH owns the copyright of images and text. Please read the operating instructions prior to first use. Pay attention to safety instructions. Keep for future use.
  • Page 7: For Your Safety

    Any other or expanded use of the biaxial mixer is a non-intended and therefore, improper use. In this case, the safety mechanisms and the protection provided by them may be compromised. Collomix GmbH is not liable for any damages caused by it. Parts of the intended use are: Complying with all information in these Operating Instructions ...
  • Page 8: Foreseeable Misuse

    The use of the equipment outside the physical use limitations described in the Chapter  "Commissioning / Operating". The modification of the control software without the prior coordination with Collomix GmbH.  Modifications on the biaxial mixer as well as add-ons and retrofits without the prior coordination ...
  • Page 9: Safety-Relevant Components

    Collomix GmbH BIAX 35/45 Safety-relevant components The machine is equipped with various safety devices. These help to avoid dangers to body and life through electrical and mechanical impacts on the persons working with the biaxial mixer and they help to limit any material damages to the system.
  • Page 10: Set-Up And Using The Mixer For The First Time

    BIAX 35/45 Collomix GmbH Set-up and using the Mixer for the first time When setting up the machine, the applicable electrical requirements and the additional information in this Operating Instructions must be followed. Content The biaxial mixer is delivered with the following: These Operating Instructions ...
  • Page 11: Activating The Perma Lubrication System

    Collomix GmbH BIAX 35/45 Activating the PERMA lubrication system The machine comes with a PERMA long-time lubricator which is to be installed before you use the © machine for the first time. Proceed as follows: For an easier installation, first open the mixing unit completely. The lubrication nipple on the hub is on the left side.
  • Page 12: Operation

    BIAX 35/45 Collomix GmbH Operation Prior to working with the machine, check all parts for their proper condition and function. Do not start the machine with defective or missing parts. Check all safety-relevant structural components of the machine for proper function before starting it.
  • Page 13: Starting The Mixing Cycle

    Collomix GmbH BIAX 35/45 Starting the mixing cycle The mixing cycle can only be started after the door is closed. Push buttons I, II, or III to start the mixing process. The corresponding mixing times are shown on the LD display above the key pad.
  • Page 14: Errors And Troubleshooting

    BIAX 35/45 Collomix GmbH Errors and Troubleshooting The troubleshooting tables in this Chapter will help you to determine whether you can troubleshoot yourself or whether you need to call customer service. DANGER Danger of death by dangerous voltage Please note that all maintenance and servicing jobs must be left strictly to authorized and suitably trained expert staff.
  • Page 15: E080 Mu Unlocked

    Collomix GmbH BIAX 35/45 Fault Description Machine condition Solutions • Close door completely E170 Error door lock • Check the door lock • Check the connection of the door lock • Check door motor Open door with the DOOR button •...
  • Page 16: Unlock Door Manually

    BIAX 35/45 Collomix GmbH Unlock door manually The machine is equipped with a safety lock, which locks the door automatically after it is closed. In the event of a malfunction or power outage, the door can be locked manually. •...
  • Page 17: Cleaning

    Collomix GmbH BIAX 35/45 Cleaning, maintenance, and service It is necessary to check, clean, and service the machine regularly to ensure continuous function. Unplug the machine from power by pulling the plug before all cleaning, maintenance, and repair work is done on the machine.
  • Page 18: Expendable Items

    Molykote© BR2 plus grease 100 g 61298 PERMA© long-time lubricator cartridge 72047 Spare parts are available under www.collomix.de. 10. Storage, disposal 10.1 Storage The storage area should be cool and dry in order to prevent corrosion on the individual parts of the machine.
  • Page 19: Appendix

    Collomix GmbH BIAX 35/45 11. Appendix 11.1 Technical Specifications BIAX 35 BIAX 45 Power supply: 230 V / 50 Hz Rated power: 1,1 kW 1,5 kW Device fuse: 10 AT Line fuse: 16 A C (RCD Typ B) Speed of mixing unit:...
  • Page 20: Dimensions

    BIAX 35/45 Collomix GmbH 11.2 Dimensions Dimensions BIAX 35 Dimensions BIAX 45 Version 1.5-18...
  • Page 21: Ec Conformity Declaration

    For your rights in the event any rectifications become necessary, please read our General Delivery Terms and Conditions. You find these on our website www.collomix.de. We are happy to send you our General Delivery Terms and Conditions on request. Version 1.5-18...
  • Page 22 BIAX 35/45 Collomix GmbH Version 1.5-18...
  • Page 23 Collomix GmbH BIAX 35/45 Version 1.5-18...
  • Page 24 BIAX 35/45 Collomix GmbH Collomix GmbH Daimlerstr. 9, D-85080 Gaimersheim Germany Tel.: +49 (0)8458 32 98 - 0 Fax: +49 (0)8458 32 98 30 www.collomix.de Version 1.5-18...