sTeam series
94
Service Information
Section Contents

Ratings

Maintenance Log
Ratings
Table 19
Ratings and engineering data
Burner
Capacity
Model
Input
Input
Gross
Oil
Gas
Output
GPH
MBH
MBH
1494
32 5
4,550
3,731
1594
35 0
4,900
4,018
1694
37 5
5,250
4,305
1794
40 0
5,600
4,592
1894
42 5
5,950
4,879
1994
45 0
6,300
5,166
2094
47 5
6,650
5,453
2194
50 0
7,000
5,740
2294
53 0
7,350
6,027
2394
55 0
7,700
6,314
2494
58 0
8,050
6,601
2594
60 0
8,400
6,888
Notes
2, 3
2, 4
5, 6
1 See the image below to specify complete model number
94
Number
of
sections
AB = Factory-assembled sections, boiler/burner unit
B = Field-assembled boiler/burner unit
H = Boiler without burner and burner mounting plate
AH = "H" unit with factory-assembled sections
P = Packaged boiler/burner unit
PH = Factory Assembled Sections No Burner Unit
PW = Factory Packaged Boiler / Field Installed Burner Unit
550-100-157/0523
boiler manual
4
SeCTion 5
Gas Ratings
Net
Net
Thermal
AHRI
Steam
Efficiency
Ratings
Ratings
%
MBH
Sq. Ft.
3244
13518
82 0
111 5
3494
14558
82 0
120 0
3743
15598
82 0
128 6
3993
16638
82 0
137 2
4243
17678
82 0
145 8
4492
18717
82 0
154 3
4742
19757
82 0
162 9
4991
20797
82 0
171 5
5241
21837
82 0
180 1
5490
22877
82 0
188 6
5740
23917
82 0
197 2
5990
24957
82 0
205 8
7
7
230030
230030
S for
O for
steam
oil
G for
gas
serviCe informaTion
69
Installation and Service Certificate
70
Notes
Oil Ratings
Net
Net
Gross
AHRI
Steam
HP
Output
Ratings
Ratings
MBH
MBH
Sq. Ft.
3,868
3363
14013
4,165
3622
15091
4,463
3880
16168
4,760
4139
17246
5,058
4398
18324
5,355
4657
19402
5,653
4915
20480
5,950
5174
21558
6,307
5484
22851
6,545
5691
23714
6,902
6002
25007
7,140
6209
25870
5, 6
7
Notes
2 Burner input based on maximum of 2,000 feet altitude For other altitudes, consult a WM
Technologies distributor
3 No 2 fuel oil — Commercial Standard Spec CS75-56 Heating value of oil = 140,000 Btu per
gallon
4 Gas pressure required at burner gas train inlet for rated burner input; based on 1,000 Btu per
cubic foot natural gas, specific gravity of 0.60. Refer to burner manual for required pressure.
5 Gross AHRI ratings have been determined under the AHRI provision governing forced draft
boiler-burner units
6 Net AHRI ratings are based on net installed radiation of sufficient quantity for the requirements
of the building
Nothing need be added for normal piping and pick-up
Water ratings are based on a piping and pick-up allowance of 1 15
An additional allowance should be made for gravity hot water systems or for unusual piping and
pick-up loads Consult the local WM Technologies distributor
7 With .10" W.C. positive pressure at flue collar.
Flue
Boiler
Outlet
Water
Dia .
Content
Thermal
Efficiency
HP
In.
Gallons
%
85 0
115 5
20
440 7
85 0
124 4
20
468 4
85 0
133 3
20
496 2
85 0
142 2
20
523 9
85 0
151 1
20
551 6
85 0
160 0
20
579 4
85 0
168 9
20
607 1
85 0
177 8
20
634 8
85 0
188 4
20
662 6
85 0
195 5
20
690 3
85 0
206 2
20
718 0
85 0
213 3
20
745 8
1
2
71
71
3
Boiler
Shipping
Weight
(approx .)
4
Lbs .
15,698
16,540
17,382
19,024
5
19,866
20,708
21,550
22,562
23,429
24,296
6
25,163
26,030
7
8
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

149415941694179418941994