Page 1
• If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service technician or the gas supplier. SERIES 4 User’s Information Manual Part number 550-141-893/0800...
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual Please read this page first Hazard definitions The following defined terms are used throughout this manual to bring attention to the presence of hazards of various risk levels or to important information concerning the life of the product.
Do not use this boiler if any part has been under water. Immediately call a qualified service technician to inspect the boiler and to replace any part of the control system and any gas control that has been under water.
Boiler Manual. service technician. Maintenance schedule Maintain the boiler using the maintenance schedule below. Have the boiler started up and serviced at least annually by a qualified service technician to ensure boiler/system reliability. Service technician (covered in Boiler Manual —...
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual User maintenance procedures Boiler must be serviced and maintained The boiler should be inspected and started annually, at the beginning of the heating season, only by a qualified service technician. In addition, the maintenance and care...
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual User maintenance procedures Monthly ... Check boiler piping Visually inspect for leaks around piping, circulators, relief valve and other fittings. Immediately call a qualified service technician to repair any leaks.
Page 7
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual User maintenance procedures Monthly ... Main burner flames See Figure 4. Remove burner input plenum cover plate “A”. Visually inspect burner flames: • main burner flame (see Figure 5):...
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual User maintenance procedures Every 6 months ... Operate relief valve To avoid water damage or scalding due to valve operation, a metal discharge line must be connected to relief valve outlet and run to a safe place of disposal.
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual Operating instructions Robertshaw 7200 gas valve FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual Operating instructions — Honeywell VR8205 and White-Rodgers 36E gas valves FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
AHE Series 4 Direct Vent Wall-Mounted Boilers — User’s Information Manual Common problems and solutions Symptom Common Causes Rapid cycling — Thermostat installed where drafts boiler turns on and or heat affect reading off frequently Heat anticipator in thermostat adjusted incorrectly...
These warranties extend only to the first retail purchaser of the boiler and only to a boiler that has not been moved from its original installation site. THE WARRANTIES DESCRIBED ABOVE ARE IN LIEU OF ALL...