Commissioning - Heatrae Sadia STREAMLINE OVERSINK Fitting Instructions And User Manual

Table of Contents

Advertisement

4.0 COMMISSIONING

DO NOT SWITCH ON THE ELECTRICAL SUPPLY UNTIL THE STREAMLINE
HAS BEEN FILLED WITH WATER AND CHECKED FOR LEAKS.
1. Check all water and electrical connections are tight.
2. Check that the thermostat and cutout capillaries are located correctly in
the element pockets.
3. Switch on the water supply and open the control valve. Fill the Streamline
and leave the water flowing for a short while to flush out the pipework.
4. Close the control valve and check the system for leaks.
5. Refit the front cover and x2 securing screws.
6. Fit the thermostat knob (see Figure 09, below).
7. Fit the control valve extension (see Figure 10, p.11)
8. Fit the control valve knob (ensure the control knob is engaged with the
control valve extension and snaps to the front cover).
9. Set the temperature. The maximum setting is 70°C and the minimum is
5°C. Rotate the thermostat knob clockwise to increase the temperature
and anticlockwise to decrease the temperature. Settings above 60°C
are recommended.
10. Switch the power on and check the water heats (see Table 1, p.4 for
heat up times).
11. Check the temperature and adjust if needed.
NOTE:
The thermostat can be locked in position to set the water temperature
to 40°C.
Remove the locking screw from the inside of the front cover and refit it to
the outside of the front cover (see Figure 09 below).
Align the locking detail on the inside of the thermostat knob to the locking
screw when fitting the thermostat knob in place.
FIGURE 09 - THERMOSTAT KNOB
THERMOSTAT
KNOB
SCREW DRIVER
RECESS
SPINDLE
10
LOCKING
DETAIL
LOCKING SCREW