X. CARE AND MAINTENANCE
 
 
If the main circuit breaker continues to trip, there is probably an
underlying electrical fault that needs attention.
• Contact your authorized Golden Technologies, Inc. provider.
• Do not keep resetting the main circuit breaker without correcting the underlying
electrical problem.

DIAGNOSTICS

The diagnostics feature of your Golden Buzzaround Lite microprocessor based motor
control board functions as follows:
• Any fault condition with the controller or with an associated system will cause the
battery meter to flash and the horn to beep.
• The flashing of the meter and beeping of the horn occurs as one flash/beep or a series
of flashes/beeps separated by a two-second pause.
• The number of flashes/beeps in each series is referred to as the "Flash/Beep Code."
• The flash/beep code indicates the nature of the condition or fault.
Flash/Beep Codes
1 Flash/Beep
• Indicates that the battery voltage (with the throttle control lever in the neutral position)
is below the required operating voltage of the scooter.
• The batteries need to be charged.
• Your Buzzaround Lite will continue to operate at reduced speeds.
• As the voltage drops you will experience a power loss.
Remedy: Charge your Buzzaround Lite's batteries. See "Batteries and Charging" in this
section.
2 Flashes/Beeps
• Indicates that the battery voltage is too low for the scooter to operate.
• At this voltage your scooter will cease operation.
• If you have charged the batteries and the condition continues, one or both of the
scooter's batteries may be at fault.
• The continuance of this condition after you have charged your Buzzaround Lite's
batteries may also indicate a problem with the battery charger.
3 Flashes/Beeps
Consult your authorized Golden Technologies, Inc. provider.