(5) On the host computer interface of the coordinator, set the terminal node device to bind the router device, so that
the terminal node device can transparently transmit data to the router device . On the host computer interface of the
coordinator device, click the "Net Cmd" menu, fill in the short address of the terminal device in the "device join
list" into the "short addr", and fill in the SN number of the terminal device into the "Source SN" , fill in the "Target
SN" for the SN of the router device, and fill in 08 FC for the "Cluster ID " (Ebyte follows the ZigBee Alliance
official "ZigBee Cluster Library" specification to customize the data transmission cluster, see details in "Ebyte
ZigBee3.0 Modules HEX Command Standard Specification") , and then click "Set Bind" .
In order to ensure that the binding settings are valid, you can click "Read Bind" to confirm whether the
binding is successful. As shown in the figure, there is a cluster ID 08 FC on the module, the Source SN is the
Copyright © 2012–20 23 , Chengdu Ebyte Electronic Technology Co., Ltd.